Two Stages RO+EDI Plant Ultrapure Water Machine Stainless Steel Fitting
Two stages reverse osmosis plant+EDI system


Treatment progress

application | ultrapure water production |
capacity | 2000 liters per hour |
model | MR-EDI-2TH |
power consume | 15kw per hour |
membranes | Filmtec BW4040 28pcs |
Water Treatment Process
1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter.
2. Quartz Sand filter--get rid of turbidity,suspended matter, organic matter, colloid, ect.
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.
4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.
5. Cartridge filter--prevent large particles into RO membrane, accuracy is 5um.
6. High pressure pump--Provide the high pressure to RO membrane
7. RO system-- main part of the plant. Reverse osmosis water production: 1m3/h,desalination rate:96~99%, System water
utilization:≥ 60%.
8. UV/ozone generator-- kill bacteria in the water
9.EDI--Use the selectivity permeation effect on anion and cation by the anion and cation exchange membrane, and exchange effect on ion by ion exchange resin, to get high purity water.