Electrochemical Hall Effect Transmitter 40~1000hz Frequency Black
TKC-KD series current sensor is dismountable, which is a open loop device based on the measuring principle of the hall effect , with a galvanic isolation between primary and secondary circuit . It can measure AC pulse and various irregular wave current in electrical isolation conditions.
Electrical data(Ta=25℃±5℃)
Type Parameter | TKC100KD | TKC300KD | TKC500KD | TKC800KD | TKC1000KD | TKC2000KD |
Unit |
Ratedcurrent(Ipn AC) | 100 | 300 | 500 | 800 | 1000 | 2000 | A |
Measuring range(Ip AC) | 150 | 450 | 750 | 1200 | 1500 | 2500 | A |
Rated output (DC) | @Ip=±Ipn ±5±1% | V | |||||
Supply voltage | ±15 ±5% | V | |||||
Power Consumption | +35,-20 | mA | |||||
Offset voltage | @Ip=0 ±30 | mV | |||||
Offset drift | @ -40~+85℃ ≤±1 | mV/℃ | |||||
output drift | @ -40~+85℃ ≤±1 | mV/℃ | |||||
Linearity | @Ip=0-±Ipn ≤0.5 | %FS | |||||
Response time | ≤200 | mS | |||||
Bandwidth | @-3dB 40~6000 | HZ | |||||
Galvanic isolation | @ 50HZ,AC,1min 5.0 | KV |
Applications
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension(for reference only)
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
Directions for use
When the current will be measured goes through a transmitter, The voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the transmitter).
The output amplitude of the transmitter can be adjusted according to users’ requirements.
Custom design in the different rated input current and the output voltage available.
Standards
General date
Value | Unit | Symbol | |
Operating temperature | -40 to +85 | ºC | TA |
Storage temperature | -40~+125 | ºC | TS |
Mass(approx) | 68 | g | M |
Characteristics chart