The TBC-TAH Series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit, the size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor, It can really measure resolution 1000:1 and it uses for precision measurement of DC, AC and pulse current.
Electrical data(Ta=25℃±5℃) |
Type Parameter | TBC50TAH | TBC100TAH | TBC200TAH | TBC300TAH | Unit |
Rated current(Ipn) | 5-50 | 10-100 | 20-200 | 30-300 | A |
Measure range(Ip) | 150(±18V,80Ω) | 300(±18V,30Ω) | 700(±18V,18Ω) | 900(±18V,2.0Ω) | A |
Turnsratio(Np/Ns)) | 1:1000 | 1:1000 | 1:2000 | 1:3000 | |
with ±12V | @50Amax 180(max) | @100Amax 75(max) | @200Amax 75(max) | @300Amax 5(max) | Ω |
@150Amax 40(max) | @300Amax 10(max) | @600Amax 5.0(max) | @600Amax 2(max) | Ω | |
with ±15V | @50Amax 240(max) | @100Amax 110(max) | @200Amax 110(max) | @300Amax 82(max) | Ω |
@150Amax 60(max) | @300Amax 15(max) | @700Amax 10(max) | @750Amax 2(max) | Ω | |
Rated output (Isn) | 5(5A)- 50(50A)±0.2% | 10(10A)- 100(100A)±0.2% | 10(20A)- 100(200A)±0.2% | 10(30A)- 100(300A±0.2% | mA |
Coil resister | 30 | 25 | 30 | 53 | Ω |
Supply voltage | ±12~±18 | V | |||
Power consumption | ≤20+IpX(Np/Ns) | mA | |||
Offset current | @Ip=0 ≤±0.2 | mA | |||
Offset drift | @ -40℃~85℃ ±0.5 | mA | |||
Response time | @100A/μS, 10%-90% <1.0 | us | |||
Linearity | @Ip=0-±Ipn ≤0.1 | %FS | |||
Galvanic isolation | @ 50HZ,AC,1min 3 | KV | |||
di/dt accurately followed | >100 | A/μs | |||
Bandwidth | @ -3db DC…100 | KHz |
Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
Directions for use |
Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
The primary conductor should be≤120℃.
The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.
The primary turns should be at the top of the sensor for the best magnetic coupling.
When the current will be measured goes through a sensor, the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor).
Custom design in the different rated input current and the output current are available.
Standards
General date |
Value | Unit | Symbol | |
Operating temperature | -40 to +85 | ºC | TA |
Storage temperature | -40 to +125 | ºC | TS |
Mass(approx) | 50 | g | M |
Characteristics chart |