Specifications
Brand Name :
M&C
Model Number :
S7/S7A
Certification :
SGS FDA ISO
Place of Origin :
Jiangsu China (mainland)
MOQ :
Negotiation
Price :
Negotiation
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
50000Pcs/Month
Delivery Time :
5-8 working days
Packaging Details :
Standard export carton /wooden case
Model :
S7/S7A
Name :
Plate Heat Exchanger Gasket/Plate
Max Design Pressure :
2.5 MPaG Max.
Plate Material :
Stainless Steel, Titanium, High Nickel Alloy, Nickel and others
Gasket Material :
NBR, EPDM, FPM, NBRHT, VITON
Surface Area :
0.07㎡
Plate Theta Angle :
55° 125°
Connection Dia :
60mm
Plate Corrugate Thickness :
2.6 mm
Plate Centre Length* Width :
394*126 mm
Plate Shape Length*Width :
498*230 mm
Description

Sondex/ Danfoss S7/S7A Heat Exchanger Plate and Rubber Gasket For Small Size Plate Heat Exchanger

S7/S7A Plate Heat Exchanger Construction

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Frame Plates Gaskets
  • The heat exchanger consists of a frame plate(head), a pressure plate(follower), a carrying bar, a lower bar and a column. Tie(clamping) bolts are used to press the plate package together. The size and number is depending on the type of heat exchanger.
  • The plate package consists of plates with a groove along the rim of the plate and around the ports. The number of plates is, as well as size and dimension, dependant on the thermal output required. Depending on the application stainless steel or titanium plates might be used
  • The groove provided in the plates holds the special gasket. The purpose of this gasket is to prevent intermixing of the media and leakage to the outside. The gaskets are selected to suit the actual combination of temperature, chemical resistance and possible other conditions to be considered. They can be supplied in Viton, Nitrile or EPDM.


S7/S7A Model Plate Heat Exchanger Specification

Surface Area 0.07㎡
Plate Theta Angle 55° 125°
Connection Diameter 60mm
Plate Corrugate Thickness 2.6 mm
Plate Centre Length* Width 394*126 mm
Plate Shape Length*Width 498*230 mm

S7/S7A Plate Heat Exchanger Technical Information

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Frame
  • Painted frame
  • Stainless steel frame, designed for the food and daily industry
  • Both frames comes with clamping bolts placed around the frame edge.
Design Pressure
  • Painted frames: 1.0/1.5/2.5 Mpa. (145/217/362 PSI)
  • Stainless steel frame: 1.0/1.6 Mpa (145/232 PSI)
Intermediate Frames
  • Intermediate frames and corner blocks in stainless steel.
Connections
  • DN150/6" flange in carbon steel, rubberlined or cladded with AISI 316 or titanium
  • DN100/4", DN125/5" and DN150/6" dairy unions
  • According to all known standards.
Plate Material
  • AISI304/316, 254 SMO and titanium.
  • Other materials available on request.
Gaskets
  • The gasket is placed in the closed gasket groove, that is formed by the plates. This design makes the plate suitable for high working pressures. The plates are strongly guided during the assembly of the plate heat exchanger. Materials: NBR, EPDM and Viton.
  • Other materials available on request.
Extra Equipment
  • Safety cover in stainless steel
  • Insulating jacket
  • Assembling spanner
  • Foundation feet for common frame
  • Instrument flange
  • Thermometer and manometer

S7/S7A Plate Heat Exchanger Gasket & Plate Pictures

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger


S7/S7A Frames

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Number of Plates L(frame length)(mm) W(mm) H(mm) Weigth max,empty(kg) Connection type
S7A IS16
7-39 429 300(11.81") 745(29.33") 111 DN50 flang or 2" threaded pipe BSP
40-76 629 135
77-150 1029 181
151-206 1329 215
207-243 1529 240
244-336 2029 297
S7A IG16
7-50 437 300(11.81") 694(27.32") 116 2" threaded pipe BSP
51-69 537 127
70-87 637 139

PHE Plate Feature

FEATURE ADVANTAGES WHAT'S IN IT FOR YOU!
A DISTRIBUTION AREA Efficient Flow Distribution
  • Prevents Mal-Distribution
B CORRUGATED PLATE PATTERN-HEAT TRANSFER AREA Promotes Turbulence, Minimize Fouling
  • Excellent heat recovery effect
  • Maximize run time
C PLATE LOCKING SYSTEMS "Corner lock" and " bubble lock" concepts ensure a stable and well aligned plate pack when the unit is closed
  • Safe and economic operation
  • High serviceability
  • Minimum service downtime
D EASYCLIP GASKET SYSTEM

Bevelled gasket edges easily clip into place using your flingers

Stays securely in place and provides high sealing integrity

  • Reliable operation
  • Easy and quick to replace
  • No special tools needed

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

PHE Gasket Type

Please check their are three common model gasket type are aways used in Sondex brand.

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

PHE Plate Type

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger
"Start plate with gasket""Left hand flow plate with gasket""Right hand flow plate with gasket" End plate with gasket"

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Thermal Long Plate Thermal Short Plate

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

  • Hanging System: Plates feature a reinforced hanging system. The hanging system helps the plates withstand the powerful tightening force, and prevents misalignment and corner collapses. This makes plates a solid investment, as the lifetime of the plates is increased and service duration is reduced.
  • Distribution area: The distribution area on plates is designed to prevent stagnant zones, and ensures an even distribution of the media across the entire plate. Furthermore, the pressure drop in the distribution area is minimal and used on the heat transmission area instead, which results in better heat transmission efficiency.
  • Heat transmission area: With a maximized heat transmission area, we are able to reduce the total number of plates needed for optimal performance. Our plate patterns are fine-tuned for each application and provide the best possible conditions for heat transfer.M&C solutions let you dial up your efficiency and dial down your energy consumption.

M&C Plate Heat Exchanger Service and Maintenance

We can help you avoid problems before they arise with a customized program, ranging from full maintenance support to ad hoc servicing. We will work out the most suitable schedule with you to carry out performance diagnostics, plate cheaning and inspections, fault checking with quick replacements, and repairs as required.

Our skilled technicians will swiftly dismantle your heat exchangers and expertly clean each plate using economic, environmentally - friendly methods. We will have your installation up and running at full capacity again in no time. We are fully equipped to perform CIP(Cleaning in Place) where possible.

If your plate heat exchanger is faulty or under-performing, our repair services will restore your installation to working order in an instant. We substitute defective or worn gaskets, as well as damaged or leaking plates, with originals or high-quality replacements that perfectly match the specifications of your installation.

We can also analyze your current setup to determine if the installation can be optimized, for example by increasing the number of plates in the heat exchanger. This is an upgrade for your entire system, as more efficient heat exchangers improve the overall performance while lowering the energy costs.

Whatever your needs, our dedicated service teams are standing by to help.

Quality Control

Our quality control inspectors meticulously examine the plates for defects. We conduct dye tests to discover potential leaks in the plates, and perform gas tests for ammonia based plate heat exchangers.

Every plate must meet our strict quality demands before being shipped to our customers, to ensure a durable solution with a long lifetime.

We are able to perform diagnostics on-site. If we uncover leaking plates in your current installation, we can replace them with high-performance plates that increase the relability and efficiency of your system.

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

PHE Problem Solving

If you have problems with your plate type heat exchanger, in most cases these can be solved by your own personnel. Please find below a summary of possible problems as well as possible causes and solutions.

A condition for the continuous proper functioning of your plate type heat exchanger is in strict compliance with the permissible values for pressure and temperature mentioned on the name plate.

Exceeding these values, even as a short-lasting pressure peaks will cause damage to the unit and be the cause of problems.

To avoid costly repairs, we advise you to have the installation work and maintenance carried out by properly trained personnel. You can also contact us.

Problem Possible Cause Possible Solution
Leakage At the connections
  • Check the rubber liners (if fitted)
  • Check the flange gasket(if fitted)
  • Check the O-ring
  • Fit the pipes tension-free
Mixing of primary and secondary circuit
  • Check the plates for holes and/or cracks
In plate package
  • Check the assembly
  • Check the condition of the gaskets
  • Check the proper position of the gasket
The operating Conditions deviate from the specification
  • Adjust the operating conditions
Insufficient Capacity Air in the system
  • De-aerate the pipe system
  • Check the pipe work for possible air traps
The operating conditions deviate from the specification
  • Adjust the operating conditions
The heat exchanger is dirty
  • Clean the heat exchanger
The connections have been interchanged
  • Redo the pipe work
Too high pressure drop Flow large the design flow
  • Adjust the flow
Channels in plate(s) blocked
  • Flush/clean
Incorrect measurements
  • Check the pressure indicator
Medium deviating from the design
  • Addition of for instance anti-freeze will increase the pressure drop
Air in the system
  • De-aerate the pipe system
  • Check the pipe work for possible air traps

Plate Heat Exchanger Pictures

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

M&C Heat Parts Company Profile

M&C Heat Parts Co., Ltd is founded in Wuxi, Jiangsu. M&C is specialized in designing and manufacturing high quality heat transfer equipment. The range of products comprises plates & gaskets, plate heat exchangers, gasketed heat exchangers and brazed heat exchangers. Thus, as one of the few producers worldwide, M&C offers solutions with optimum thermodynamic designs for different industries and virtually all applications.

M&C provide you with one-stop accessories service, multuple-brand & multiple model alternatives for your choice. We'll meet all your requirements of plate heat exchanger and keep your machine running contunously through our rich storage and quick response.

Moreover, we have a strict quality control and after-sales service system, from material purchasing to finished product package until the product received in good condition. Our products have been widely used all over the world in various fields.

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

M&C Plate Heat Exchanger Plates & Gaskets Other Models Recommend

Sondex/Danfoss - S4A, S7, S20, S21, S22, S41, S43, S47, S65, S81, S86, S100, S120, S130, SFD7, SFD13, SW19 and so on;

APV/SPX - H17, N25, N35, A055, A085, J060, J092, J107, M92, M107, K55, K71, B110, B134, P105, P190, SR1, SR2, TR9GN, TR9AL and so on;

Tranter/Swep - GX12, GL13, GC26, GC51, GX26, GX51, GX42, GX64, GX85, GX91, GX140, GX145 and so on;

API/Schmidt - Sigma 7, Sigma 9, Sigma 13, Sigma 26, Sigma 27, Sigma 36, Sigma 66, Sigma 106, Sigma 229, Sigma Star 45, Sigma Star 90 and so on;

Vicarb - V4, V13, V20, V28, V45, V60, V100, V110, V130 and so on;

Hisaka - EX11, EX15, EX15, LX026, LX195, LX395, LX595, RX135, RX395, RX595, UX115, UX225, UX395, UX495, UX815, UX995 and so on;

GEA - VT04, VT10, VT20, VT40, VT80, VT405, VT805, VT1306, NT50M, NT50X, NT100S, NT150S, NT150L, NT250M, NT250L and so on;

Funke - FP04, FP05, FP14, FP16, FP08, FP22, FP31, FP40, FP41, FP70, FP100, FP120 and so on;

Thermowave - TL200SS/PP, TL250SS/PP, TL400SS/PP. TL650SS/PP and so on;

DHP - DX143, DX146, DX20V, DX20DL, DX20DM, DX30S, DX36M and so on;

LHE - HT101, HT102, HT104, HT151, HT152, HT202, HT232, HT233 and so on;

M&C Plate Heat Exchanger Goods ready to Delivery

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Send your message to this supplier
Send Now

Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Ask Latest Price
Watch Video
Brand Name :
M&C
Model Number :
S7/S7A
Certification :
SGS FDA ISO
Place of Origin :
Jiangsu China (mainland)
MOQ :
Negotiation
Price :
Negotiation
Contact Supplier
video
Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger
Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger
Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger
Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger
Sondex Danfoss S7 S7A Heat Exchanger Plate Rubber Gasket For Small Size Plate Heat Exchanger

Jiangyin M&C Heat Parts Co.,Ltd

Verified Supplier
7 Years
jiangsu, wuxi
Since 2011
Business Type :
Manufacturer, Exporter
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement