Thermocouple compenstaing wire is used to connect the electrode ( cold side of thermocouple ) with display instrument in order to form a temperature measurement system. The working temperature is -25~200 ℃. Our plant mainly manufacture type KX,NX,EX,JX,NC,TX,SC/RC,KCA,KCB, and WREC compensating wire for thermocouple,and they are used in temperature measurement instruments and cables. Our thermocouple compensating products are all made abiding by GB/T 4990-2010‘Alloy wires of extension and compensating cables for thermocouples’( Chinese National Standard) ,and also IEC584-3‘Thermocouple part 3-compensating wire‘(International standard).
EMF of compensating wire and the tolerance
Themocouple No. indexing |
Compensation wire tpye |
Usag Classification | Measuring junction temperature/℃ |
Standard EMF value/μV |
Precision grade | General grade | ||
Tolerance μV | Thermal EWF range μV |
Tolerance μV | Thermal EWF range μV |
|||||
S or R | SC or RC | G | 100 | 646 | ±30 | 616~676 | ±60 | 586~706 |
H | 100 | 646 | ---- | ---- | ±60 | 586~706 | ||
200 | 11441 | ---- | ---- | 1381~1501 |
Compensating wire reciprocating resistance
Compensation wire type |
Reciprocating resistance at 20℃ Ω/m (Less than) | ||||
0.2mm² | 0.5mm² | 1.0mm² | 1.5mm² | 2.5mm² | |
SC or RC | 0.25 | 0.1 | 0.05 | 0.03 | 0.02 |