Specifications
Brand Name :
WellCare
Model Number :
AETE-02B
Certification :
CE Certificate
Place of Origin :
CHINA
MOQ :
10
Payment Terms :
L/C, T/T, Western Union, MoneyGram
Delivery Time :
within 3 days after payment
Packaging Details :
Sterilization Packaging in Carton
Price :
Negotiation
Instrument Classification :
Class II
Application :
Internal Hemorrhoids Surgery
Product Name :
Rubber Band Ligator
Ligation points :
3~8 locations
Ligation Material: :
Elastic thread (Silica gel materials)
Attachment :
Anoscope
Sterilization :
EO Sterilization
Warranty :
2 Years
Description

Minor surgical wound Rubber band ligator with anoscope, Double layer ligation

Charcateristic of Rubber Band Ligator:
1. Significantly release postoperative pain and bleeding, and speed up recovery ;
2. Extralarge cartridge capacity to hold more tissue;
3. Simple and easy manual operation with a tissue thickness indicator;
4. Special screw to reduce operation time significantly.

Product Information: Elastic thread ligator for hemorrhoids:

It is a new ligator which can automatically tighten elastic thread through automatic tension drive trigger device. Four advanced technology have been awarded national patent. It is characterized with minimal invasive, security, painless and easy operation, which is suited to surgery for hemorrhoids in any stage.

Product Application: Internal Hemorrhoids & Mixed Hemorrhoids

Product Characteristics

Minimal invasive: No affection to patients’ normal life, they are barely required to lie in bed after surgery and will recovery in a week time due to tiny operational wound.
Security: No damage to functional tissues, nearly eradicating postoperative bleeding, no sequelae and foreign body residual as well.
Painless: Dispensable anesthesia for patients during operation, painless during intraoperative and postoperative process, having slight distending feeling and free to normal life after operation.
Easy operation: Elastic thread ligation and self-tightening tissues are finished by one trigger at the same time, completed by one person with one hand only

Technology

Elastic thread ring is used instead of rubber ring material, which has excellent performance in traditional hemorrhoid ligation. Traditional rubber ring is used as binding material, its disadvantage is that rubber is easy to aging, fatigue and deterioration. Elastic thread ligation is a new way to replace the rubber ring with elastic line, which is made of special polymer material with Silica gel. It has unique performance, avoids a series of inherent defects of rubber, and can obviously improve the binding effect.

Elastic thread ring can be extremely tight, which basically avoiding postoperative bleeding. When the elastic thread is tied on the target tissue, the inner diameter of the loop can be further reduced by automatically tightening the elastic thread. Therefore, the binding of the target tissue is extremely tight, the ulcer surface after tissue falling off is very small (close to zero), and the hemorrhoidal vessels are completely occluded, which basically avoids the risk of postoperative bleeding

More advantages than traditional device

Compared with rubber band ligator

The different material of ligator makes two key indicators of ligator for hemorrhoids change, so, our product improves the scale and effect of surgery.

 One of the key indicators is the length of inner bore of ligation band

The minimum length of inner bore of rubber band is 1.5 mm, which is more likely to make the ligated tissues necrosis incompletely and increases the risk of bleeding when the knot detaches.

The length of inner bore of elastic band is nearly zero, which makes the ligated tissues necrosis completely without haemorrhage.

‚ Another key indicator is elastic recoil of ligation band

Rubber band may slip leading to ineffective treatment. It may also reduce the elasticity resulting in the ligated tissues necrosis incompletely and increasing the complications because of storage time and material.

Compared with PPH(TST)

There is no section, wound and scar, so it recovers quickly.

No foreign body residual.

PPH(TST) cut many tissues, which more likely to form stricture of anus and residual titanium nail and result in complications, such as perforation, rectofistula and vaginal fistula. While our product just ligates mucosa without bleeding and other risks.

Theory: Double Layer Ligation

Minor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 Locations

Feature:

Minor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 Locations

Minor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 LocationsMinor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 LocationsMinor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 Locations

Send your message to this supplier
Send Now

Minor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 Locations

Ask Latest Price
Brand Name :
WellCare
Model Number :
AETE-02B
Certification :
CE Certificate
Place of Origin :
CHINA
MOQ :
10
Payment Terms :
L/C, T/T, Western Union, MoneyGram
Contact Supplier
Minor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 Locations
Minor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 Locations
Minor Surgical Wound Rubber Band Ligator Double Layer Ligation 3 - 8 Locations

well care (wuhan) medical technology co.,ltd

Active Member
6 Years
hubei, wuhan
Since 2015
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
10000000-20000000
Employee Number :
100~120
Certification Level :
Active Member
Contact Supplier
Submit Requirement