Blood centrifuge is suitable for accurate determination of blood cell ratio value and can also be used for precipitation separation of trace blood and solution.The small blood treatment amount is large, convenient blood extraction, short centrifugation time, accurate detection, convenient to use.The capillary equipped with the sample is placed symmetrically into the rotor. After starting the instrument, the rotor rotates around the axis, rotating while creating a relative centrifugal force to separate the solution.
Blood centrifuge is suitable for accurate determination of blood cell ratio product value, and can also be used for precipitation separation of trace blood and solution.The amount of blood extraction is small, and the blood (available earlobes) has a large disposal amount, convenient blood extraction, short centrifugation time, accurate detection, high work efficiency, and complete supporting facilities.Suitable for biological, chemistry, medicine, genetics, medicine, hospital, laboratory separation of blood, organisms, chloroplast, protein nucleic acid, viruses, etc.
characteristic:
1. The H / T12MM blood centrifuge is a routine test for the serology of blood type.Microcolumn gels, and washed with red blood cells.Immune detection and other tests to develop a special centrifuge.Set up a variety of procedures according to different tests, accurate control and convenient to use.
2. Widely used in clinical medicine, biochemistry, immunology and other fields. It is a conventional instrument for centrifugal precipitation in the laboratory.
3. It is mainly used to determine the blood ratio of blood cells, and the separation of trace blood and trace solutions.It is one of the preferred products of the protein nucleic acid laboratory.
technical parameter | An H / T12MM immune blood centrifuge |
Maximum rotational speed (r/min) | 4000 |
Maximum centrifugation force (g) | 2200 |
Speed accuracy | ± 50 r/min (customizable to demand, multiple of 10) |
Control and drive system | Large-moment DC brushless motor, microcomputer control |
Time range | 1min-99h59min, with continuous centrifugation and instantaneous centrifugation |
noise | ≤60dB(A) |
source | AC220V 50HZ |
power | 120W |
External size | 550×440×330 mm |
weight | 35 Kg |
Rotor parameters:
The rotor name | maximum speed | centrifugal force | use |
The SERO rotor was washed with the red blood ball | 4000 | 1842 |
Blood type judgment, blood type agglutination reflects the observation; Cross-fitness test, conduct globulin test; Blood ball cleaning, serum, plasma extraction; |
Lymphballs were washed with HLS rotor | 4200 | 2200 |
Lymphid balls were isolated and cultured cells were isolated; Removal of platelets (thrombin treatment); Cleaning of lymphatic balls; |
Blood type card rotor | 4000 | 1824 | 6 Column, 8 column micro blood type cards, 12 cards |