80W Aluminum Housed Wirewound Dynamic Braking Resistor For Vfd
Structure :
1.The resistors core components are made of insulating and high-temperature resistant materials as the resistors framework,evenly wound with high-quality alloy wires.
2.Metal aluminum shell potted with high insulation non-combustible electronic paste,so that the aluminum shell and the resistance core components are closely combined into a solid entity,not affected by external air,vibration and dust,high stability and thermal conductivity.
3.The aluminum shell is made of high-quality industrial 6063 aluminum,and the surface is high-temperature anodized to achieve attractive appearance and great heat dissipation.
Features
1. Economical,preferred product in the new energy vehicles precharge industry.
2. High stability,impact resistance and easy installation;Good reliability & high consistency.
3. Ends outgoing:flying leads or metal terminals.
4. In or external temperature switch available;
5. Inductive or Non-inductive available;
6. Used for loading,braking,pulse,charging,discharging,starting,buffering,discharging,ect.
Specification
Performance Charactertics | ||
Test | Conditions of Test | Testing Results |
Resistance Tolerance | Testing Voltage ≤3V,Ambient Temperature 25℃ | B---D---F---G---J--K |
Temperature Coefficients | R0:Room Temperature(T0)Resistance Value R1:Room Temperature T0+100℃(T1)Resistance Value | ±100~±250PPM/℃ |
Rated Load | 40℃,rated voltage,1hour | △R≤±(3%+0.1Ω) |
Short Time Overload | 5 times rated power for 10s;10 times rated power for 5s;25 times rated power for 1s | △R≤±(2%+0.1Ω) |
Dielectric Withstand Voltage | 2 times Rated Power Voltage +1kv AC 60s (with grounding), leakage current 2.5mA ; 2 times Rated Power Voltage +2kv AC 60s (with grounding), leakage current 2.5mA ; | △R≤±(0.1%+0.05Ω) |
Insulation Resistance | 1000V DC | 50M-1000MΩ1Min |
Terminal Tensile Strength | wire diameter ≤1.5 with 20N,wire diameter ≥1.5 with 40N, | No off |
Vibration resistance | 1.5mm,10-55-10Hz,each 2hours | No damage,No off |
Load Life | at rated voltage,90 min "On",30 min "Off" ,total 500hours | △R≤±(3%+0.1Ω) |
Thermal Shock | At 30℃,30min,-55℃,15min | △R≤±(0.5%+0.1Ω) |
Humidity Resistance | Temp.:40±2℃ ,Humidity: 90%-95%.240hours | △R≤±(3%+0.1Ω) |
Low Temperature Resistance Testing | store at -65℃±3℃ for 2H | △R≤±(1%+0.1Ω) |
High Temperature Resistance Testing | store at 70 ℃± 2 ℃ for 16h, connect the rated voltage DC circuit for 1s | △R≤±(1%+0.1Ω) |
Non-flammability | 10 times rated power, power on for 5s | without combustion |
Applications
Widely used in frequency converter,elevator,hoisting,ship,electric power,welding,power supply,military industry,aviation,wind power generation,solar power generation,automation equipment,railway system and other industries,and can be made into load banks according to the customers requests.
Products Image