Specifications
Brand Name :
Fanke High-voltage
Model Number :
Z-VI series
Certification :
ISO9001
Place of Origin :
China
MOQ :
One unit
Price :
Negotiable
Payment Terms :
T/T
Supply Ability :
10units/week
Delivery Time :
20-25 work days
Packaging Details :
Export standard wooden case with fumigation free
Application :
DC Hipot Tester and leakage current measurement
Test object :
Electric Arresters , Insulators , Power Cable
Test Range :
made by order
Duty Cycle :
30mins for one time
Current Accuracy :
1.0% of the reading ± 2digit
Voltage Accu :
1.0% of the reading ± 0.2KV
Description

Portable DC High Voltage Generator , DC High Voltage Test Kit , DC Hipot And Leakage Current Tester

I. Product Description

Z-VI Series DC hipot tester is used for DC high voltage withstand test and leakage current measurement for zinc oxide arrester, magnetic blowing arrester, power cables, generators, transformers, switches and other equipment. It is suitable for electric power branch, power department of factories, scientific research units, railway, chemical industry, and power plants.


II. Feature

  • Smaller, lighter, more beautiful, more reliable, easy to operate, fully functional, easy field use, the new century, the best and reliable products.
  • With the most advanced manufacturing technology, the first application of the latest PWM frequency pulse width modulation. By high-power IGBT devices, the adoption of high-frequency technology to improve the frequency, frequency up to 100kHz, making the output voltage more stable and ripple factor smaller.
  • The main components are made of the advanced technology components imported from United States, Germany, Japan and other countries, durable, immune of directly continuous short-circuit discharge.
  • Voltage regulation and high stability, smooth voltage regulating, output voltage regulation with single multi-turn potentiometer, a smooth step-up process, adjustable high precision. Voltage regulation accuracy of better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor of better than 0.5%.
  • Negative output, zero start, continuously adjustable, over-voltage protection, over current protection, zero protection, ground protection, specific disconnection protection etc. Automatic protection circuitry is strong, reliable and well-protected, so safe operation.
  • Addition of high-precision 75% VDC-1mA function do bring great convenience to MOA measurement. The instrument control box with the 75% of the voltage function keys. During arrester test, when the current rise to 1000 uA, open the 0.75 button, then voltmeter, ammeter shows that 75% of the value of the data, after it immediately back to zero, and while the fine-tune voltage back to zero on the knob, and pressing the green button should immediately cut off high-voltage and turn off the power switch. And then do other tests.
  • Built-in support base with three feet, increasing the stability of voltage multiplier tube.


III. Technical data

Specification
Technical parameters

60/2 100/2 100/10 160/2 180/2 200/2 300/3

100/200
3/2

200/300
3/2

Others
Voltage output (kV) 60 100 100 160 180 200 300 100/200 200/300

600~800
kV

Customize

Current output
(mA)

2 2 10 2 2 2 3 3/2 3/2

Power output
(W)

120 200 1000 320 360 400 900 400 600

Charging current
(mA)

3.0 3.0 12.0 3.0 3.0 3.0 4.5 4.5/3.0 4.5/3.0

Chassis weight
(kg)

4.3 4.3 5.3 4.3 4.3 4.4 5.5 4.5 8.1

Dimension of
voltage multiplier tube
(mm)

Φ80
×500

Φ80
×620

Φ80
×770

Φ80
×770

Φ110
×770

Φ110
×770

Φ160
×1250

Φ110
×800

Φ110
×1350

Weight of voltage multiplier tube
(kg)

6.3 6.8 7.5 7.2 7.2 7.2 7.6 7.5 12.6
Polarity Negative voltage polarity, zero voltage start, continuously adjustable
Working power AC 220V ±10%; 50 Hz
Voltage accuracy 1.0% ±1d, Max. resolution 0.1% kV
Current accuracy 1.0% ±1d, Max. resolution 0.1% uA
Over-voltage error ≤1.0%

0.75
Switching error

≤0.5%
Ripple coefficient ≤1.0%
Voltage stability ≤0.5%, if line-voltage variation is ±10%; Random fluctuation
Manner of working Intermittent service, for 30 min at rated load; for 10 min at 1.1 times of rated voltage
Ambient temperature -15℃~50℃
Relative humidity If 25℃,less than 90%(non-condensing)
Altitude Below 2000m















































IV. Supply List:
1, Control cabinet 1 set
2, High-voltage multi-voltage tube 1 piece(or 2 pieces)
3, Power line 1 piece
4, High-frequency output cable 1 piece
5, Fuse 10A 3 pieces
6, Instruction manual 1 copy
7, Certificate of quality 1 copy
8, Factory report 1 copy
9, Telescopic discharging rod 1 piece
10, Ground wire for discharging rod 1 piece
11, Current-limiting resistance 1 piece
12, Microampere meter 1 piece
13, Shielding wire and clamps 1 set

Send your message to this supplier
Send Now

Lightweight DC Hipot Test Equipment Leakage Current Tester Easy To Operate

Ask Latest Price
Brand Name :
Fanke High-voltage
Model Number :
Z-VI series
Certification :
ISO9001
Place of Origin :
China
MOQ :
One unit
Price :
Negotiable
Contact Supplier
Lightweight DC Hipot Test Equipment Leakage Current Tester Easy To Operate

WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

Active Member
7 Years
hubei, wuhan
Since 2003
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
6000000-10000000
Employee Number :
100~120
Certification Level :
Active Member
Contact Supplier
Submit Requirement