Specifications
Brand Name :
Fanke High-Voltage
Model Number :
FKGST 12KV
Certification :
ISO9001
Place of Origin :
China
MOQ :
One unit
Price :
Negotiable
Payment Terms :
T/T
Supply Ability :
10units/month
Delivery Time :
10 work days
Packaging Details :
Export standard wooden case with fumigation free
Usage :
Capacitance & Tan Delta Tester within 12KV or 12KV
HV output :
0-12KV
Test object :
Motor , power generator and so on.
Test range :
50pF~1uF; 0~12KV
Anti-interference :
Variable Frequency Method, 5mA
Test Accuracy :
Reading*1.5%
Description

12KV Transformer Capacitance & Tan Delta Tester , Automatic Tan Delta Tester , Generator Tan Delta Tester

I. Products Description

FKGST 12KV Tan Delta (dissipation factor) Tester consists of variable frequency power, tan delta bridge, testing transformer and standard capacitor inside the tester. Variable frequency power can produce five kinds of frequency: 45Hz, 50Hz, 55Hz, 60Hz and 65Hz under which test can be done. Variable frequency technique adopted in this tester can ensure high accuracy in high interference environment.

Model FKGST Automatic 12KV Capacitance &Dissipation Factor Test Set is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test. The meter is whole in one designed: including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits. It’s also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it’s running automatically and then outputs the results on LCD display and prints the results automatically.


II. Test principle
12KV Transformer Capacitance &  Tan Delta Test Set Automatic 0-12KV HV Output
Fig 1 Wiring Diagram of Main Power
RX1---Sampling resistance in ungrounded test specimen measurement
RX2---Sampling resistance in grounded test specimen measurement
CN---Standard capacitor
RN---Sampling resistance of reference signal
CVT---Voltage output terminal in CVT measurement by means of self-excitation.

III. Technical Parameters
1. Input: 220V+5%, 50Hz, 1KVA
2. Output:voltage:0~12kV (0.5kV/step to raise voltage)

current:100mA continuous

Max. 200mA, 5min on/15min off (10kV)

Max.160mA, 5min on/15min off (12kV)

3.Test range:
3.1 voltage:0~12kV resolution:1V
3.2 capacitance: 10kV, 50pF~60000pF(50Hz)
12kV, 50pF~44000pF(50Hz)
0.5kV, 50pF~1uF(50Hz)
3.3 Max. resolution:0.01pF
3.4 Tan delta:0~10% Maximum resolution:0.00001

4.Accuracy:
4.1 voltage(RMS):+200V
4.2 capacitance:+(Reading*1.0%+1pF)
4.3 in ungrounded test specimen measurement +Reading*1.5%+1pF
4.4 in grounded test specimen measurement tan delta:+reading*1.0%+0.0005

5.Operational environment:
5.1operation temperature:-5℃~55℃
5.2 humidity:<85%
5.3 storage temperature:-20℃~55℃


III. Configuration:


SN NAME Qty
1 FKGST Automatic 12KV Capacitance &Dissipation Factor Tester 1set
2 10 meters Hipot measuring signal lines (red) 1pec
3 10 meters measuring signal lines (black) 2pecs
4 8 m CVT Low voltage output line 1pec
5 Power line 1pec
6 8 m Earth line 1pec
7 Spare printing paper 1pec
8 5A fuse 1pec
9 Feltpad 1pec
10 Manual 1pec
11 certificate of inspection 1pec
12 accessory case fro connection lines 1pec
















Send your message to this supplier
Send Now

12KV Transformer Capacitance & Tan Delta Test Set Automatic 0-12KV HV Output

Ask Latest Price
Brand Name :
Fanke High-Voltage
Model Number :
FKGST 12KV
Certification :
ISO9001
Place of Origin :
China
MOQ :
One unit
Price :
Negotiable
Contact Supplier
12KV Transformer Capacitance &  Tan Delta Test Set Automatic 0-12KV HV Output

WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

Active Member
7 Years
hubei, wuhan
Since 2003
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
6000000-10000000
Employee Number :
100~120
Certification Level :
Active Member
Contact Supplier
Submit Requirement