Details:
Conductor: tinned copper
Construction: 7/0.16
Pairs: 3
Pair twisted: required
Insulation: FEP
Shield: stainless steel braided
Jacket: Silicone
Type: customized Multi Pair signal Cable
Thank you for providing the details about the 3 pairs shielded customized signal cable.
This cable is designed for use in applications where signal integrity is critical. The cable has three pairs of conductors, each made of tinned copper with a construction of 7/0.16, providing excellent conductivity and stability in signal transmission. Each pair of conductors is twisted to reduce crosstalk and improve signal quality.
The insulation material used is FEP, which is known for its high temperature resistance, excellent dielectric properties, and low signal attenuation. The cable is shielded with a stainless steel braided shield, which provides excellent EMI/RFI protection, ensuring that the signal remains clean and stable even in the presence of external electromagnetic interference.
The jacket is made of silicone, which is highly resistant to heat, moisture, chemicals, and UV radiation, making the cable suitable for use in harsh environments. The cable is rated as a customized multi-pair signal cable, which means it can be customized to meet specific application requirements.
this 3 pairs shielded customized signal cable is a reliable, high-performance cable that can be used in a variety of applications where signal integrity is crucial. Its combination of high-quality materials, shielding, and customization options make it an excellent choice for use in demanding environments where the cable must meet specific requirements.
ARMORED CABLE | ||||||||
PAIRS | nominal conductor diameter | nominal insulation thickness | inner thickness | inner diameter | armor steel diameter | Jacjet thickness | Max. Overall Diameter | estimated weight |
pairs | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
2(0) | 0.9 | 0.3 | 0.8 | 5.7 | 0.9 | 1.3 | 10.1 | 200 |
5 | 0.9 | 0.3 | 1 | 9.4 | 0.9 | 1.4 | 14.1 | 370 |
10 | 0.9 | 0.3 | 1.1 | 13 | 1.25 | 1.5 | 18.6 | 610 |
20 | 0.9 | 0.3 | 1.2 | 16.8 | 1.25 | 1.6 | 22.7 | 930 |
30 | 0.9 | 0.3 | 1.4 | 19.9 | 1.6 | 1.7 | 26.7 | 1390 |
50 | 0.9 | 0.3 | 1.6 | 25.4 | 1.6 | 1.9 | 32.6 | 1940 |
100 | 0.9 | 0.3 | 1.9 | 35.5 | 2 | 2 | 44.1 | 3700 |
SHIELDED | ||||||||
2(0) | 0.9 | 0.3 | 0.8 | 6.2 | 0.9 | 1.3 | 10.6 | 220 |
5 | 0.9 | 0.3 | 1 | 9.9 | 0.9 | 1.4 | 14.6 | 380 |
10 | 0.9 | 0.3 | 1.1 | 13.5 | 1.25 | 1.5 | 19.1 | 630 |
20 | 0.9 | 0.3 | 1.2 | 17.3 | 1.25 | 1.6 | 23.2 | 955 |
30 | 0.9 | 0.3 | 1.4 | 20.4 | 1.6 | 1.7 | 27.2 | 1415 |
50 | 0.9 | 0.3 | 1.6 | 25.9 | 1.6 | 1.9 | 33.1 | 2000 |
100 | 0.9 | 0.3 | 1.9 | 36 | 2 | 2 | 44.6 | 3750 |
NON-ARMORED CABLE | ||||||||
pairs | nominal conductor diameter | section area | insulation thickness | jacket thickness | Max. Overall Diameter | estimated weight | ||
pairs | mm | mm2 | mm | mm | mm | Kg/Km | ||
NON-SHIELDED | ||||||||
2(0) | 0.9 | 0.64 | 0.3 | 1.3 | 5.7 | 45 | ||
5 | 0.9 | 0.64 | 0.3 | 1.4 | 9.4 | 115 | ||
10 | 0.9 | 0.64 | 0.3 | 1.5 | 13 | 205 | ||
20 | 0.9 | 0.64 | 0.3 | 1.6 | 16.8 | 380 | ||
30 | 0.9 | 0.64 | 0.3 | 1.7 | 19.9 | 570 | ||
50 | 0.9 | 0.64 | 0.3 | 1.9 | 25.4 | 920 | ||
100 | 0.9 | 0.64 | 0.3 | 2 | 35.5 | 1820 | ||
SHIELDED | ||||||||
2(0) | 0.9 | 0.64 | 0.3 | 1.3 | 6.2 | 50 | ||
5 | 0.9 | 0.64 | 0.3 | 1.4 | 9.9 | 125 | ||
10 | 0.9 | 0.64 | 0.3 | 1.5 | 13.5 | 215 | ||
20 | 0.9 | 0.64 | 0.3 | 1.6 | 17.3 | 390 | ||
30 | 0.9 | 0.64 | 0.3 | 1.7 | 20.4 | 580 | ||
50 | 0.9 | 0.64 | 0.3 | 1.9 | 25.9 | 940 | ||
100 | 0.9 | 0.64 | 0.3 | 2 | 36 | 1850 |