Z-79B
Details:SIHF GLP
Description: 2 CONDUCTOR POWER CABLE
Details:
Conductor: tinned copper
Section area: 1mm2
Construction: 81/0.12
Pairs: 1
Twisted: required
Filler: Al Foil
Shield: Al foil
Binder: Poly tape
Overall shield: tinned copper wire braided
Coverage: more than 90%
Jacket silicone rubber
O.D.: 7.6mm
Rated Temp: 200degree
Rated Voltage: 300v/500v
Type multi core
AWG | No. of Cores | Conductor cross section mm^2 | Nominal OD mm | Copper weight kg/km | Gross Weight kg/km |
18 | 2 | 0.75 | 7.2 | 14.4 | 88 |
18 | 3 | 0.75 | 7.6 | 21.6 | 99 |
18 | 4 | 0.75 | 8.1 | 29 | 121 |
18 | 5 | 0.75 | 9.2 | 36 | 147 |
18 | 6 | 0.75 | 9.9 | 43 | 169 |
18 | 7 | 0.75 | 9.9 | 50 | 178 |
17 | 2 | 1 | 7.6 | 19 | 98 |
17 | 3 | 1 | 8 | 29 | 119 |
17 | 4 | 1 | 8.8 | 38 | 139 |
17 | 5 | 1 | 9.7 | 48 | 167 |
17 | 6 | 1 | 10.4 | 58 | 185 |
17 | 7 | 1 | 10.4 | 67 | 194 |
16 | 2 | 1.5 | 8.3 | 29 | 126 |
16 | 3 | 1.5 | 8.7 | 43 | 143 |
16 | 4 | 1.5 | 9.6 | 58 | 170 |
16 | 5 | 1.5 | 10.4 | 72 | 198 |
16 | 6 | 1.5 | 11.4 | 86 | 245 |
16 | 7 | 1.5 | 11.4 | 101 | 256 |
16 | 8 | 1.5 | 12.7 | 116 | 315 |
16 | 10 | 1.5 | 14 | 144 | 370 |
16 | 12 | 1.5 | 14.5 | 173 | 408 |
16 | 14 | 1.5 | 15.6 | 202 | 471 |
16 | 16 | 1.5 | 17 | 231 | 541 |
16 | 18 | 1.5 | 17.8 | 260 | 599 |
16 | 20 | 1.5 | 18.3 | 288 | 630 |
16 | 24 | 1.5 | 20.4 | 346 | 760 |
14 | 2 | 2.5 | 9.7 | 48 | 165 |
14 | 3 | 2.5 | 10.2 | 72 | 238 |
14 | 4 | 2.5 | 11.5 | 96 | 268 |
14 | 5 | 2.5 | 12.7 | 120 | 315 |
14 | 6 | 2.5 | 13.7 | 144 | 370 |
14 | 7 | 2.5 | 13.7 | 168 | 385 |
14 | 12 | 2.5 | 17.6 | 288 | 608 |
12 | 2 | 4 | 11.5 | 77 | 255 |
12 | 3 | 4 | 12.2 | 115 | 299 |
12 | 4 | 4 | 13.4 | 154 | 365 |
12 | 5 | 4 | 15.1 | 192 | 455 |
12 | 6 | 4 | 16.4 | 230 | 525 |
12 | 7 | 4 | 16.4 | 269 | 556 |
10 | 2 | 6 | 12.9 | 115 | 326 |
10 | 3 | 6 | 13.7 | 173 | 401 |
10 | 4 | 6 | 14.8 | 230 | 485 |
10 | 5 | 6 | 16.8 | 288 | 602 |
10 | 6 | 6 | 18.2 | 346 | 701 |
10 | 7 | 6 | 18.2 | 403 | 736 |
8 | 2 | 10 | 17.3 | 192 | 543 |
8 | 3 | 10 | 18.4 | 288 | 652 |
8 | 4 | 10 | 20.6 | 384 | 825 |
8 | 5 | 10 | 22.5 | 480 | 987 |
6 | 2 | 16 | 20.2 | 308 | 748 |
6 | 3 | 16 | 21.5 | 462 | 909 |
6 | 4 | 16 | 23.4 | 616 | 1183 |
6 | 5 | 16 | 26.2 | 770 | 1393 |
4 | 2 | 25 | 23.8 | 480 | 1046 |
4 | 3 | 25 | 26 | 720 | 1347 |
4 | 4 | 25 | 28.3 | 960 | 1678 |
2 | 2 | 35 | 27.2 | 672 | 1378 |
2 | 3 | 35 | 29 | 1008 | 1846 |
2 | 4 | 35 | 32.3 | 1344 | 2240 |
1 | 2 | 50 | 31.4 | 960 | 1869 |
1 | 3 | 50 | 33.5 | 1440 | 2384 |
1 | 4 | 50 | 37.2 | 1920 | 2702 |
2/0 | 2 | 70 | 35.3 | 1344 | 2482 |
2/0 | 3 | 70 | 38.3 | 2016 | 3314 |
2/0 | 4 | 70 | 42.5 | 2688 | 4074 |
3/0 | 2 | 90 | 41.4 | 1824 | 3380 |
3/0 | 3 | 90 | 44.8 | 2736 | 4299 |
3/0 | 4 | 90 | 49.8 | 3648 | 5339 |
4/0 | 3 | 120 | 48.8 | 3465 | 5277 |
4/0 | 4 | 120 | 54.1 | 4620 | 6571 |
2 CONDUCTOR POWER CABLE is a custom cable, so you may find in spite of a power application, we still use shield for this cable. For 1pair FEP insulation, we used Al foil wrapping and overall tinned copper braid in order to make sure this cable will not be interference from outer ambient.
FEP insulation and silicone Jacket combination is commonly used for those high end clients, who requires high temperature working environment and still keep the flexibility of the whole cable.