y-08
this is a wonderful cable which has a long story. Our client has a power station project, and the temperature sensor instruments need an 8 pairs 16awg thermocouple cable in type K. unfortunately, our client failed 2 times before met us.
Because this multi pair cable need very high precision for temperature measuring, so we prepared every pair with twisted and shielded procedures together with AL foil and TC drain wire as individual shield, we made the same construction for general shield.
Since this instrument cable need buried under earth, we use stainless steel braid as the armor to protect the cable from press. This multi cable actually collect almost all the necessary element of the thermocouple conductor, PVC insulation, pair twist, individual shield, general shield, armor, etc.
Once Dingzun cable arrived, the end users give good ratings after installation, they were happy, this project eventually runs correctly.
Dingzun shows great capability and profession to manage the complicated multi pair cables, and do welcome more clients can give the opportunities to have the order cooperation.
ARMORED CABLE | ||||||||
PAIRS | nominal conductor diameter | nominal insulation thickness | inner thickness | inner diameter | armor steel diameter | Jacjet thickness | Max. Overall Diameter | estimated weight |
pairs | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
2(0) | 0.9 | 0.3 | 0.8 | 5.7 | 0.9 | 1.3 | 10.1 | 200 |
5 | 0.9 | 0.3 | 1 | 9.4 | 0.9 | 1.4 | 14.1 | 370 |
10 | 0.9 | 0.3 | 1.1 | 13 | 1.25 | 1.5 | 18.6 | 610 |
20 | 0.9 | 0.3 | 1.2 | 16.8 | 1.25 | 1.6 | 22.7 | 930 |
30 | 0.9 | 0.3 | 1.4 | 19.9 | 1.6 | 1.7 | 26.7 | 1390 |
50 | 0.9 | 0.3 | 1.6 | 25.4 | 1.6 | 1.9 | 32.6 | 1940 |
100 | 0.9 | 0.3 | 1.9 | 35.5 | 2 | 2 | 44.1 | 3700 |
SHIELDED | ||||||||
2(0) | 0.9 | 0.3 | 0.8 | 6.2 | 0.9 | 1.3 | 10.6 | 220 |
5 | 0.9 | 0.3 | 1 | 9.9 | 0.9 | 1.4 | 14.6 | 380 |
10 | 0.9 | 0.3 | 1.1 | 13.5 | 1.25 | 1.5 | 19.1 | 630 |
20 | 0.9 | 0.3 | 1.2 | 17.3 | 1.25 | 1.6 | 23.2 | 955 |
30 | 0.9 | 0.3 | 1.4 | 20.4 | 1.6 | 1.7 | 27.2 | 1415 |
50 | 0.9 | 0.3 | 1.6 | 25.9 | 1.6 | 1.9 | 33.1 | 2000 |
100 | 0.9 | 0.3 | 1.9 | 36 | 2 | 2 | 44.6 | 3750 |
NON-ARMORED CABLE | ||||||||
pairs | nominal conductor diameter | section area | insulation thickness | jacket thickness | Max. Overall Diameter | estimated weight | ||
pairs | mm | mm2 | mm | mm | mm | Kg/Km | ||
NON-SHIELDED | ||||||||
2(0) | 0.9 | 0.64 | 0.3 | 1.3 | 5.7 | 45 | ||
5 | 0.9 | 0.64 | 0.3 | 1.4 | 9.4 | 115 | ||
10 | 0.9 | 0.64 | 0.3 | 1.5 | 13 | 205 | ||
20 | 0.9 | 0.64 | 0.3 | 1.6 | 16.8 | 380 | ||
30 | 0.9 | 0.64 | 0.3 | 1.7 | 19.9 | 570 | ||
50 | 0.9 | 0.64 | 0.3 | 1.9 | 25.4 | 920 | ||
100 | 0.9 | 0.64 | 0.3 | 2 | 35.5 | 1820 | ||
SHIELDED | ||||||||
2(0) | 0.9 | 0.64 | 0.3 | 1.3 | 6.2 | 50 | ||
5 | 0.9 | 0.64 | 0.3 | 1.4 | 9.9 | 125 | ||
10 | 0.9 | 0.64 | 0.3 | 1.5 | 13.5 | 215 | ||
20 | 0.9 | 0.64 | 0.3 | 1.6 | 17.3 | 390 | ||
30 | 0.9 | 0.64 | 0.3 | 1.7 | 20.4 | 580 | ||
50 | 0.9 | 0.64 | 0.3 | 1.9 | 25.9 | 940 | ||
100 | 0.9 | 0.64 | 0.3 | 2 | 36 | 1850 |