Equipment for dielectric loss measurement of transformers, transformers, bushings, capacitors, arresters, etc.
● Use complex current method to measure capacitance, dielectric loss and other parameters.
● Integrated model with standard capacitor and high voltage power supply for on-site testing and field wiring reduction.
● With reverse wiring low voltage shielding function.
Features:
1. Complex number current method to measure capacitance, tgδ, and other parameters. Auto, High accuracy
2. Reliable measuring data in heavy electromagnetic interference environment
3. Large screen LCD display, menu prompts, easy reading and easy operation
4. Microprocessor control, auto measurement ( after choose measuring methods)
5. Compact structure with standard capacitor and high voltage power supply inside, easy wiring.
6. High accuracy, oil dielectric loss measurement to be done by matching with oil cup and test lines
7. CVT self-excited test function, one time measurement to get C1, C2 capacitance and dielectric loss
8. Grounded specimen test adopts ivddv technology to get stable measurement data
9. Low-voltage shielding function, when 220kV CVT bus is grounded, C11 can be disconnected for 10kV GST
10. HV (+10kV) dielectric loss factor test function ( after match with HV transformer or resonance devices)
11. Grounding protection function, over current protection function
12. electric shock protection function, auto cut off power when operator accidentally get an electric shock.
Parameters:
Accuracy: Cx: ±(reading×1%+1pF), Tgδ: ±(reading×1%+0.00040) Anti-interference index: within 200% Capacitance range: Internal HV: 3pF-60000pF/10kV 60pF-1μF/0.5kV External HV: 3pF-1.5μF/10kV 60pF-30μF/0.5kV Resolution: Maximum 0.001pF, 4 valid figures. tgδ range: unlimited, resolution 0.001%, auto identifying specimen to be capacitor, inductor or resistor. Test current range: 10μA-1A Internal HV: voltage setting range: 0.5-10kV Maximum output current: 200mA Buck-boost method: continuous smooth regulation Test frequency: 45, 50, 55, 65Hz single frequency, 45/55Hz, 55/65Hz, 47.5/52.5Hz auto dual frequency External HV: In case of UST, maximum test current: 1A, power frequency or variable frequency 40-70Hz In case of GST, maximum test current 10kV/1A, power frequency or variable frequency 40-70Hz CVT self-exciting low voltage output: Output voltage 3-50V, output current 3-30A Measuring duration: About 40s, depending on measuring method Input power supply: 180V-270VAC, 50Hz±1%, powered by main supply or generator Computer interface: Standard RS232 interface Printer: WH-A7 mini-type thermal printer Environment temperature: -10℃-50℃, Relative humidity: <90% Overall dimension:460×360×350mm, weight:28kg |
Wuhan GDZX Power Equipment Co.,Ltd OFFER YOU :
1: FACTORY DIRECT PRICE.
2: NICE QUALITY.
3: QUICK SHIPPING WITHIN 15 DAYS.
4: SMALL ORDER WELCOME..
5: ONLINE PAYMENT.
6: SUPPORT One year free warranty, three years quality assurance, lifetime maintenance.
7: AFTER SALES SERVICES 24/7