* Tests any boiler up to & over 5MW / 50 mbar draught with high suction pump
* Measures CO to 100,000ppm / 10%, HC to 5000ppm & CO2 to 20%
* Option to measure NO, NO2, SO2 & H2S
* Large graphic colour display & keypad
* Wirelessly connects optional KANE LINK devices to measure flow & return, air flow & air quality
* Tests air conditioning & refrigeration system superheat & subcool - wireless KANE LINK devices available soon
* MCERTS (pending) tests with optional KANE GCU Gas Chiller Unit
* Backed by KANE CARE 10 year warranty - We promise to never let you down or your money back
* Install, commission & service any heating & hot water system using any fossil, biomass & HVO fuel
* Optional environmental sensors test to local regulation
* Accurate NO2 & SO2 measurements with optional KANE-GCU gas conditioning unit
* Safety checks - CO in rooms & around appliances
* Combustion performance & efficiency tests
* Flue draught & gas pressure / system tightness tests
* Flow & return, air flow & air quality tests
* Air conditioning & refrigeration superheat & subcool test
* Backed by KANE CARE - We promise to never let you down or your money back
* Natural Gas x2 & Town Gas
* LPG, Biogas & Kinsale Gas
* Butane, Propane & Gascor
* Light oil & Heavy oil
* Coke, Coal & Anthracite
* Up to 5 user fuels
Measures | O2 to 21% ppm |
CO to 10,000ppm H2compensated & 100,000ppm / 10% | |
CO2 to 21% with 40% over range | |
HC to 5,000ppm | |
Temperature - inlet / flue gas / differential / ambient / flow & return | |
High accuracy differential pressure meter +/- 160mbar | |
NO to 5,000ppm - option | |
NO2 to 1,000ppm - option | |
SO2 0-5,000ppm - option | |
H2S to 200ppm - option | |
Calculates | CO/CO2 ratio |
Combustion efficiency, | |
Excess air / Lambda | |
NOx - if NO fitted | |
Superheat & Subcool - with optional KANE LINK devices available soon |