Specifications
Brand Name :
UST
Model Number :
HydrogenPower
Certification :
UL 913,CSA, SIRA05 ATEX II 2G EEx ia d IIB T3 IECEx Ex ia d IIB T3
Place of Origin :
Germany
MOQ :
1
Payment Terms :
L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram,Paypal
Packaging Details :
Carton Case
Function :
Handheld multi-range gas leak detector for Hydrogen (H2)
Gas Detection :
Hydrogen (H2)
Gas Sensor :
MOX gas sensor element (GGS 1000 + 6000 series)
Detection Range :
1 ppm ... 999 ppm, 0,1 Vol%... 4,0 Vol%
Response Tiime :
2 s
Flow Rate :
40 ml/min
Size :
180*50 *28 mm
Weight :
0.44 kg
Description


Handheld Multi-range Gas Leak Detector for Hydrogen (H2)

OVERVIEW

Hydrogen Power Multi-Range Handheld Gas Leak Detector With Suction Pump Led Display

SPECIFICATION

Measurement range (H2) 1 ppm ... 999 ppm, 0,1 Vol%... 4,0 Vol%
Resolution 1 ppm / 0,1 Vol% depending on the display range
Response time 2s
Time to operation readiness 120s
Gas sensor MOX gas sensor element (GGS 1000 + 6000 series)
Flow rate of suction pump 40 ml/min
Dimensions (Length x Width x Height) 180 mm x 50 mm x 28 mm (without sensor extension flex)
Sensor extension flex (Length) 300 mm
Net weight 440 g (without charger)
Rechargeable battery power pack

4 x 1,2 V NiMH, to be charged from the mains using the charger supplied with

the gas leak detector

Operating time (power pack is fully charged) 6 h
Allowable operating temperature -5 °C… +40°C
Allowable storage and transportation temperature/humidity -25 °C … +70°C / 20… 80 % r.H. (non-condensing)
Allowable operating, transport and storage conditions Any contamination of the gas sensor must be avoided. The application, transport and storage environment has to be free of any contamination, particularly protected against chemical substances, e.g. silicones. In particular directly contact with substances containing, silicones, sulphurous substances or non-desorbing inorganic components or contaminations (e.g. smoke, fumes, oils, greases or evaporating liquids) may cause damaging the sensor or to changes in the sensor resistance and/or in the sensor characteristics. Possible consequences are reduced sensitivity, display of misleading concentration values, or display of a background concentration.
Conformity 2011/65/EU: Restriction of the use of Hazardous Substances Directive (RoHS)

FEATURES & BENEFITS

1. Handheld multi-range gas leak detector with suction pump for the selective detection of Hydrogen (H2)
2. Display of the detected gas concentration value from low ppm range up to "Lower Explosive Limit" (LEL) in Vol%
3. Additional display of the detected gas concentration value from low ppm range up to 1000 ppm by bar graph
4. Automatic measuring range change-over
5. Additional display of concentration thresholds (10, 100, 1000 ppm and 1 Vol%) by LED (optional customized factory calibration)
6. Intermittent tone signal reflecting concentration value by speed and continuous tone signal at 1 Vol% (can be switched off)
7. Automatic zero setting on air after switch on
8. Automatic sensor check with error recognition

Send your message to this supplier
Send Now

Hydrogen Power Multi-Range Handheld Gas Leak Detector With Suction Pump Led Display

Ask Latest Price
Brand Name :
UST
Model Number :
HydrogenPower
Certification :
UL 913,CSA, SIRA05 ATEX II 2G EEx ia d IIB T3 IECEx Ex ia d IIB T3
Place of Origin :
Germany
MOQ :
1
Payment Terms :
L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram,Paypal
Contact Supplier
Hydrogen Power Multi-Range Handheld Gas Leak Detector With Suction Pump Led Display
Hydrogen Power Multi-Range Handheld Gas Leak Detector With Suction Pump Led Display

Beijing HiYi Technology Co., Ltd

Verified Supplier
5 Years
beijing, beijing
Since 2001
Business Type :
Manufacturer, Trading Company
Total Annual :
10000000-15000000
Employee Number :
30~50
Certification Level :
Verified Supplier
Contact Supplier