Independently tested by TÜV SUD to EN50379 the new KANE9206 Quintox is a cost effective & versatile emissions monitoring solution. Customised to your specific requirement the KANE9206 Quintox uses electro-chemical sensors to monitor Carbon Monoxide, Nitrogen Dioxide, Nitric Oxide, Sulphur Dioxide, Hydrogen Sulphide, and Oxygen.
Combine up to five electro-chemical sensors with our infra-red measurement technology to monitor Carbon Monoxide (up to 10%), Carbon Dioxide & Hydrocarbons.
1. The KANE9206 Quintox Standard Kit | ||||||
KANE9206 Standard Kit Includes: Handset, Base Unit & Power Supply | ||||||
Measures | 02 | CO (H2 Compensated) | CO2 (calculated) | Temperature | Pressure | Efficieny |
0-25% | 0-10000ppm | 0-20% | 0-1100°C | 0-150 mbar | 1-100% |
2. Select additional sensor options | ||||||
Optional Sensor Upgrades | The Quintox can be fitted with any combination of up to five additional electro-chemical sensors plus one complete infra-red module | |||||
Electro-Chemical Sensors | NO (Hi Range) 0-5000ppm KNO1H/Q | NO (Lo Range) 0-100ppm KNO1L/Q | NO2 0-1000ppm KNO2/Q | SO2 (Hi Range) 0-5000ppm KSO2H/Q | SO2 (Lo Range) 0-100ppm KSO2L/Q | H2S 0-1000ppm KH2S/Q |
Infra-Red Module KHC/Q | CO 0-10% | HC 0-5000ppm | CO2 0-20% | Please note: if Infra-Red Module KHC/Q is fitted, the Hi/Lo CO Protection Solenoid & Pump KHPURQ is also required. |
3.Select a probe | |||||||
Optional Probes | Depending on your requirement a selection of high quality stainless steel probes with integral thermocouples are available Hi-Temp = 1100°C/2140°F Standard Temp = 600°C/1112°F | ||||||
| Hi Temp Probe 1 metre removable shaft KMCHLP6 | Hi Temp Probe 285mm removable shaft KMCHP6 | Hi Temp Smoke Probe 1 metre removable shaft KMCHSLP6 | Hi Temp Smoke Probe 285mm removable shaft KMCHSP6 | Smoke Probe 285mm removable shaft KMCSP6 | Professional Probe 1 metre removable shaft KMCLP6 | Professional Probe 285mm removable shaft KMCP6 |
4.Optional upgrades | ||
Used in conjunction with the heated probe & heated line, the sample conditioning unit comprises: a peltier fan cooled chiller assembly, a peristaltic pump to automatically remove condensate, the control electronics & power supply module | ||
Sample Conditioning Unit KMDM110/230 | Heated Probe KMHP1200 | Heated Line KMHL3000 |
Hi/Lo CO Protection Solenoid & Pump KHPURQ Must be used with Infra-Red Module KHC/Q | Hi/Lo purge protection allows a standard ppm sensor to be fitted providing accurate readings at below 20ppm. When approaching over-range the solenoid operates & switches the gas flow to the electro-chemical sensor from flue gas to fresh air. The pump is then used to flush out the CO sensor & protect it from over-range. CO readings continue to be taken using the CO channel of the Infra-Red Module KHC/Q | |
Pumped Water Trap WTS9206P | The pumped water trap empties itself on a regular basis & so protects the analyser from condensate overflow, this allows long term unattended monitoring | |
Heater - Toxic Sensors KHSA | Enables toxic sensors to operate effectively at below 0°C ambient temperature. The heater maintains temperature at +5°C |
Combining innovation & ease of use the AUTO600 Portable Diesel Smokemeter is designed to meet official test standards.
Ideal for:Car & Light Commercial Workshops, PSV Workshops, Fleet Operators, Pre-Compliance Testing, Servicing vehicles, Local Authority and Environmental Testing.