The MIC500-OZ ozone gas analyzer is equipped with an advanced automatic zero-point correction function. This feature ensures consistent zero-point stability, even when exposed to ozone, and represents a patented innovation by our company. The analyzer supports continuous 24-hour operation without the need for downtime.
Detection Principle: Utilizes the UV dual-beam absorption method, making it ideal for real-time monitoring of ozone generator output concentrations and tail gas ozone concentration measurements.
Measurement Range: 0–300 g/NM³ / 0–200 g/NM³
Features: Includes a proprietary automatic zero-point correction system, dual-path UV absorption technology, durable UV LED light source sourced internationally, and ensures stable and reliable concentration detection during continuous operation.
*Features: Patented technology, with automatic zero correction, dual-path UV absorption principle, foreign long-life UV LED light source, continuous operation, to ensure the stability of detection concentration.
*Test Method: Double light path ultraviolet light absorption method, long life light source system, high measurement accuracy.
*Principle of Measurement: According to Lambert-Peale law, accurate measurement by photo-metric absorption principle.
*Light Source System: Foreign long-life UV light source system (UV LED light source (with Lens)) , free warranty for 2 years.
*Use: Indoor installation, configuration of power and signal terminals.
*Light Cell System: separated light cell technology, no leakage, high pressure, high flow resistance to sampling gas impact.
*Intelligent Compensation: built-in temperature and pressure compensation and display, with light source automatic compensation function.
*Operation Mode: User can select manual zero-setting and automatic zero-setting according to the running state, and can set the automatic zero-setting time.
*Display Unit: g/NM3, MG/NL optional.
*Data Display: High-definition color touch screen, high-concentration range set gas quality flow, real-time output display (optional) .
*Output Function: 4 -20 Ma, RS485 Communication, two sets of alarm point output, electronic flow meter input, etc. .
*Standard Configuration: anti-corrosion flow-meter, ozone tail gas destroyer, intake filter.
Model | MIC500-OZ |
Measuring range | 0-300g/Nm3 |
Optional ranges | 0-200g/NM3,0-100G/NM3,0-50G/NM3,0-1000PPM; |
Light source life | Approx. 30,000 - 50,000 hours |
Sampling method | positive pressure sampling, negative pressure sampling (optional) |
Display interface | 4.3" touch screen operator interface |
Content interface | Ozone concentration, temperature, pressure |
Auxiliary functions | Temperature compensation, pressure compensation |
Display units | g/Nm3, mg/NL, %WT optional |
Display resolution | 0.01g/Nm3 |
Gas flow | 0.5L ± 0.2L/min |
Input pressure | <0.1 MPa |
Concentration error | 0.5% FS max |
Linearity error | 0.5% FS max |
Zero point drift | <±0.3%.FS |
Response time | 0.03 s for signal, 0.3 s for display |
Ambient temperature | -20 to 50°C |
Piping connection | Quick screw (stainless steel) |
Tandem sample aperture | Φ8 (8mm*6mm) (optional) |
Bypass sampling aperture | Φ6 (6mm*4mm) |
Communication method | RS-485 |
Output mode | 4-20mA (active) |
Relay signal | Relay signal for high alarm point, relay signal for low alarm point |
Power supply | AC 110-220V |
Dimensions | 230mm (height) * 330mm (width) * 150mm (depth) |
Note | 1mg/L = 1g/m3 = 467PPM. |
Free warranty | 24 months (mainframe sensor) |
Range | Sampling Method | Application Area |
0-300g/Nm3 | Positive pressure sampling with pressure and temperature compensation | Real-time detection of ozone generator outlet concentration. |
0-100g/Nm3 | Positive pressure sampling with pressure and temperature compensation | Real-time detection of ozone generator outlet concentration. |
0-50g/Nm3 | Positive or negative pressure sampling with pressure and temperature compensation | Ozone generator outlet or exhaust ozone concentration detection. |
0-1000ppm | Positive or negative pressure sampling with pressure and temperature compensation | Real-time measurement of ozone concentration in the chamber. |
0-100ppm | Positive or negative pressure sampling with pressure and temperature compensation | Real-time measurement of ozone concentration in space or room. |
Ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry, food and drinking water industry, space disinfection industry, pool disinfection industry, flavor synthesis industry and other industries using ozone generator.
With 20 years combined experience, Zetron develops, manufacture and market a complete range of gas detection equipment to protect people from hazardous conditions in the industry, research and commercial applications. Today Zetron is in providing gas detection equipment, services and solutions to keep your personnel and plant safe. Our complete product range includes portable gas detector, fixed detection systems, landfill gas analyzer, remote laser methane gas detector, as well as air quality monitoring systems.
As part of our focus on quality, Zetron is ISO9001:2005 and SGS certified and our products have acquired the CE, RoHS, FCC, and ATEX certifications.
So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.
The list of countries still expanding.....
We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.