| 768VDC250A BMS Communication protocol: Rs485, CAN, LAN * 4U standard 19inch case * Efficient, stable and reliable * size:W482*H180*D500mm |
12S-24S BMU(Slave) 12S-24S BMU has 8pcs of temperature sensors, Fan voltage 48V(17S-24S 12V), voltage detection range 0-5V,12V power supply,consumption less 20mA, CAN2.0 B communication | Wire harness-Signal acquisition wire 18 Pin+20Pin wire, standard length is 600mm,900mm,1200mmtempreture sensor wire: standard length is 600mm,900mm,1200mm Fan wire: 600mm | Wire harness-communication wire Communication wire is connecting from the master BMS to each BMU with a cascade connection, the last port is for terminal resistance |
Product Name | BMS |
Model no. | RBMS07-S20-250A768V |
protecting method | MCCB+Contactor |
Rated Current range | -250A~250A |
Voltage Range | 384V-1000V |
Current Sampling Accuracy | 1.0%FSR |
Communication interface with PCS | RS485/CAN |
Communication interface with BMU | CAN |
Communication interface with SBMS | RS485/CAN |
Communication with monitoring software/EMS | Ethernet |
Support IAP upgrade | Yes |
Support HMI display and parameter | No(Optional plug-in) |
Insulation detection | Yes(Optional) |
High voltage power module | Support DC start (optional) |
Dry contact output (normally open) | No |
Maximum qty of BMUs | 20 |
Power | 24VDC(18~28V) |
Power consumption | ≤25W(Three wire systems); ≤15W(Two wire systems) |
Size(W*H*D)mm | 4U (482*180*500) |
Way out | Front |
Tap center | Support(Optional) |
Net weight | 23kg |






Lead Time
-
Quantity(Sets) | 1 - 5 | 6 - 20 | 21 - 50 | >50 |
Est. Time(days) | 15 | 20 | 25 | To be negotiated |
Our comapny
Hunan Group Control Energy Technology Co., Ltd.(GCE) is a high-tech company specializing in the research and development of BMS and lithium battery peripheral equipment.
We are ready to share Information, Experience, and Solutions in BMS (Battery Management System) Solar Power Investment.