Stainless Steel Double Core Mineral Insulated Cable With Stainless Steel Sheath
600 Volt Rated Voltage Double Core Mineral Insulated Heating Cable is a type of mineral insulated heating cable of double conductors with rated voltage 600 Volt. Stainless steel sheath series mineral insulated heating cables can meet the requirements of high temperature conditions and high heating power (up to 269W/m). Pasia provide stainless steel sheathed heating cable with the highest temperature up to 600 ℃. Conductor resistance value ranges from 28000 Ω /km to 19.2 / km. Mineral insulated cable has excellent properties of mechanical strength and corrosion resistance.
The needs of different power can be met based on Pasia series resistance type heating cable.
Heating Cable Instruction Code
MI SS-B 16N12220/60/2520/220/E1
No. 1 2 3 4 5 6 7
NO. | Item | Detail |
1 | sheath material | SS |
2 | cable component structure | See table 1 |
3 | cable codes | See table 2, 3 and 4 |
4 | Heating cable length | in m |
5 | Heating cable power | in unit of W |
6 | Heating cable voltage | in V |
7 | cold end specification | See table 5 |
Cable Code
1 6 N 12220
No. 1 2 3 4
No. | Item | Detail |
1 | Number of core wires | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | Conductor material | K,N |
4 | cold resistance×10000 | 12220=1.222Ω/m×10000 |
MI Heating Cable Specification (600V Double Cores)
Cable Code | Diameter | +20℃ Standard Resistance | Maximum Manufacturing Length | Unit Weight |
mm | Ω/m | m | kg/km | |
26N11700 | 8.7 | 1.1700 | 180 | 216 |
26N15500 | 7.2 | 1.5500 | 195 | 203 |
26N24000 | 5.0 | 2.4000 | 234 | 178 |
26N41500 | 3.8 | 4.1500 | 280 | 160 |
26N110000 | 2.9 | 11.0000 | 300 | 152 |
26N280000 | 2.1 | 28.0000 | 350 | 140 |
Cond End Specification
Model :A, D, E | Model: B | |||||
Maximum Voltage (V) | Maximum Current (amps) | Cond End Specification | Maximum Current (amps) | Cold End Specification | ||
(British) | (Metric) | (British) | (Metric) | |||
600 | 15 | E1 | M1 | 20 | E1 | M1 |
600 | 20 | E1 | M1 | 25 | E1 | M1 |
600 | 30 | E2 | M2 | 40 | E2 | M2 |
600 | 50 | E2 | M2 | 70 | E2 | M2 |
600 | 70 | E2 | M2 | 100 | E2 | M2 |
Note 1: E1 means 1/2" NPT;
E2 means 3/4" NPT;
M1 is thread diameter M15;
M2 is the diameter of thread M20
Note 2: the length of standard cold end cable is 2 meters. If special required, please contact our professionals
Application
Nuclear Industry | Construction-Asphalt Heating |
Metal Manufacturing Industry- low melting point alloy melting | Tank heating |
Extruder barrel heating | High temperature industrial pipe heat tracing |
Anti-coagulation or viscosity drop for process medium | All kinds of industrial electric heaters |