Commercial boilers main feature
1, Boiler design, production, and inspection are strictly carried out in accordance with the Commercial boilers inspection regulations, JB/T 10094-2002 industrial boiler pass conditions, and JB/T 1619-2002 boiler shell boilers to ensure long-term work.
2, The main body is a three-way pipe structure with a full-humid back flow in the shell and shell.
The flame is slightly positive pressure in the large chamber, stretching, low heat load, less harmful NOx emissions, and heat-receiving area, according to the heat exchange capacity and temperature of the furnace. The power is proportional, the effective radiation is heated, and the heat absorption of the furnace is higher than the total heat absorption.
3, the corrugated furnace and the threaded pipe structure, strength, and each part needs heat.
4, The Commercial boilers main welds are welded and docked, and X-ray and ultrasonic non-destructive testing ensures that the welding meets the steam gauge requirements.
Commercial boilers technical data sheet as follow (for reference only) :
Project, unit and data, model | WNS0.5-1-Y(Q) | WNS1-1-Y(Q) | WNS2-1-Y(Q) | WNS3-1-Y(Q) | WNS4-1.25-Y(Q) | WNS5-1.25-Y(Q) | WNS6-1.25-Y(Q) | WNS8-1.25-Y(Q) | WNS10-1.25-Y(Q) | ||
Rated evaporation | t/h | 0.5 | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | |
Rated steam pressure | MPa | 1 | 1 | 1 | 1 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Rated steam temperature | °C | 184 | 184 | 184 | 184 | 194 | 194 | 194 | 194 | 194 | |
Rated feed water temperature | °C | 20 | 20 | 20 | 20 | 20 | 20 | 105 | 105 | 105 | |
Total heated area | M2 | 15.4 | 30.7 | 60.9 | 90.5 | 124.7 | 128.3 | 136.3 | 187 | 217.6 | |
exhaust temperature | °C | 230 | 230 | 230 | 230 | 220 | 220 | 220 | 220 | 220 | |
Gas boiler efficiency | % | 91.78 | 91.44 | 91.77 | 92.14 | 92.3 | 92.03 | 92.15 | 91.87 | 92.29 | |
Applicable fuel | / | Diesel, heavy oil, natural gas, liquefied gas, city gas | |||||||||
Diesel oil.Heavy oil.Natural gas.City gas | |||||||||||
Ringman black | / | <1 level | |||||||||
Fuel consumption | Diesel | Kg/h | 31.5 | 63 | 125.5 | 189 | 253 | 315 | 376 | 501 | 628 |
heavy oil | Kg/h | 33.02 | 66.99 | 131.72 | 197.55 | 263.12 | 328.55 | 394.26 | 525.57 | 680 | |
natural gas | Nm3/h | 37.5 | 75 | 151 | 225 | 300 | 375 | 449 | 600 | 750 | |
Liquefied gas | Nm3/h | 12.66 | 25.38 | 50.68 | 76.01 | 101.24 | 126.41 | 151.7 | 202.2 | 252.8 | |
City gas | Nm3/h | 75 | 150 | 302 | 450 | 600 | 750 | 898 | 1200 | 1500 | |
Boiler weight | Empty furnace | T | 2.7 | 4.87 | 7.32 | 10.1 | 12.86 | 14.7 | 15.3 | 18.6 | 21.3 |
Full of water | T | 3.7 | 6.4 | 12.8 | 16 | twenty two | 24.7 | 25.5 | 32.5 | 38 | |
using electric | V | 380V/50Hz | |||||||||
Main steam valve diameter (DN) | Mm | 50 | 65 | 65 | 100 | 100 | 125 | 125 | 150 | 150 | |
Safety valve diameter (DN) | Mm | 50 | 50×2 | 50×2 | 50×2 | 50×2 | 80 50 | 80 50 | 80×2 | 80×2 | |
Drain valve diameter (DN) | Mm | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |
Feed pump model | SS | JGGC1 | JGGC2 | JGGC2 | JGGC4 | JGGC4 | JGGC6 | JGGC8 | JGGC12 | JGGC12 | |
Chimney caliber | Mm | Φ316 | Φ316 | Φ400 | Φ530 | Φ530 | Φ530 | Φ530 | Φ680 | Φ680 |