Industrial 14Mw-2.45Mpa SZS powder&oil fired hot water boiler output 90% efficiency
Main design principles of gas hot water boiler:
1. Low investment in boiler equipment
-- gas boilers choose higher furnace load, so as to reduce the furnace volume, because the heating surface pollution, ligation, wear and other problems.
Higher smoke velocity and smaller size of convection heating surface are available.
The structure of gas-fired boilers with the same capacity as coal-fired boilers is compact, the size is small, the weight is light and the equipment investment is obviously reduced by reasonable arrangement of convection tube bundles.
-- gas boilers use pipelines to transport gas as fuel and do not require fuel storage equipment.
Also do not need to blow ash, dust remover, slag removal equipment, and fuel dryer and other ancillary equipment, is the system greatly simplified.
2. Low operation cost
-- gas boiler has strong adaptability to heat load and flexible adjustment in the system.
-- less auxiliary equipment, faster start-up and no fuel preparation system can reduce various consumption brought by preparatory work, and the power consumption is lower than that of coal-fired boilers.
-- no need for steam heating fuel and drying fuel, steam consumption is low.
-- less impurities in the gas, the boiler will not occur high, low temperature heating surface corrosion, the continuous operation cycle of the boiler is long.
3. Low maintenance cost of equipment
-- gas boiler system equipment is simple, so there are few maintenance projects and low maintenance costs.
-- since there is no slagging and corrosion of the heating surface at high and low temperature, it is not necessary to replace the pipe fitting of the heating surface.
Typical SZS series steam boiler technical parameter list | ||||||
model | SZS10-1.6-QY | SZS15-1.6-QY | SZS20-1.6-QY | SZS25-1.6-QY | SZS35-1.6-QY | SZS45-1.6-QY |
Rated evaporation t/h | 10 | 15 | 20 | 25 | 35 | 45 |
Rated steam pressure MPa | 1.6 | |||||
Rated steam temperature °C | 204 | |||||
Feed water temperature °C | 105 | |||||
Boiler design thermal efficiency% | 93.5%~100.6% | |||||
Common fuel | Natural gas / light diesel | |||||
Combustion method | Forced ventilation, micro-positive pressure combustion | |||||
Exhaust gas temperature °C | 55~150 | |||||
Fuel consumption (natural gas) Nm3/h | 703 | 1055 | 1406 | 1758 | 2461 | 3164 |
Gas supply pressure (natural gas) mbar | 20~30 | 30~50 | 30~50 | 30~50 | 50 | 50~200 |
Maximum transport weight t | 27 | 32 | 37 | 42 | 51 | 35 |
Maximum transport size m | 6.7x3.2x3.5 | 7.2x3.4x3.4 | 7.7x3.6x3.9 | 8.5x3.8x4.1 | 9.6x4.1x4.3 | 10.0x3.5x3.8 |
Mainframe dimensions (including platform, energy saver) | 9.0x5.6x4.4 | 9.9x5.6x4.0 | 10.5x5.7x4.6 | 11.3x6.0x4.8 | 12.4x6.6x5.0 | 13.0x6.8x5.2 |
Description: | ||||||
1. The boiler is mainly designed with natural gas and light diesel oil. It is also suitable for city gas, liquefied petroleum gas, biogas, coke oven gas and mine gas. | ||||||
2. The fuel consumption is calculated based on the calorific value of natural gas 36006KJ/Nm3 and the calorific value of light oil 42705KJ/kg. | ||||||
3. We follow the principle of continuous improvement and improvement of product performance. The data of the new generation products may be changed. The data in the table is for reference only. |