Natural gas burner for boiler industrial thermal oil heater gas burner curing furnace two stage modulated
YXG series small and medium two-stage Natural gas burner for boiler
Using natural gas (NG, LNG) and liquefied petroleum gas (LPG) as fuel, fully automatic double-stage fire (large and small fire) control, large/small automatic switching according to equipment load control, meeting high precision load control requirements .
It is widely used in small and medium-sized boilers, heating furnaces, spraying equipment, drying equipment, heat treatment equipment and other thermal energy equipment to achieve applications with certain load control accuracy requirements.
1, Safe and reliable automatic program control
1. Fully automatic program control operation, which can control large/small fire switching according to load parameter setting to realize automatic control of output force;
2. The ion-induced or UV-UV monitoring device is used to realize the accidental flameout protection function to ensure the flame combustion safety and stability;
3. Configure gas pressure and air pressure safety protection switch, and at the same time, it can easily realize external interlock control to ensure safe operation;
2, Good combustion performance
1. The large/small fire state can be freely set within the processing range, and the load output control is more flexible and convenient;
2. When the large/small fire is switched, the air volume can be automatically adjusted according to the setting, ensuring that the large/small fire state is realized.
Good combustion state;
3, Flexible configuration
1. The proportional control of small and medium-sized burners can be realized by adding a proportional proportional adjustment device to meet the requirements of higher precision load control;
2. It can be adapted to different origin supply modes by increasing the configuration of gas pressure regulating and filtering devices;
Natural gas burner for boiler will supply u highest buying experience :
1. CE standard ,comply with 90/396/EEC;PIN63AP6680
2. EMC comply with 89/336/EEC
3. Burner comply IP40,EN60529 protection
4. Burner gas valve comply with EN676
5. Two-stage operation (high/low flame).
6. Compatible with any type of combustion chamber, according to EN303 standard
7. High blowing efficiency, low electrical input, low noise.
8. Air-gas mixing at blast-pipe.
9. Maintenance facilitated by the fact that the mixing unit can be removed without having to remove the burner from the boiler.
Natural gas burner for boiler with famous part ,long life time:
SIEMENS CONTROLLER
DUNGS VALVE
DANFOSS NOZZLE
SUNTEC OIL PUMP
BRAHMA/PARKER SOLENOID VALVE
FIDA TRANSFERMA
SIEMENS SERVOMOTOR
Natural gas burner for boiler DATASHEET FOR REFERENCE
NATRUAL GAS BURNER EMAIL: bettysun001@vip.126.com | |||||||
MODEL | GAS COMBUSTION | BURNER OUTPUT | MAIN SUPPLY | Motor | CONTROL METHOD | ||
NM3/HR | KW | ||||||
MIN | MAX | MIN | MAX | KW | |||
SINGLE STAGE CONTROL | |||||||
YXG5 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG6 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG11 | 4.8 | 10 | 48.8 | 99 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG10 | 4.8 | 99 | 48.8 | 99 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG17 | 7 | 17 | 69 | 169 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG20 | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG30 | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG35 | 9 | 35.8 | 90 | 359 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG34 | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | ONE STAGE |
YXG40 | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | ONE STAGE |
YXG50 | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 0.55 | ONE STAGE |
TWO STAGE CONTROL | |||||||
YXG20P | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG30P | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG35P | 9 | 35.8 | 90 | 358 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG34P | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | TWO STAGE |
YXG40P | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | TWO STAGE |
YXG50P | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG60P | 25 | 75 | 248 | 738 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG100P | 28 | 101 | 280 | 995 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG120P | 35 | 121 | 350 | 1200 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG150P | 42 | 144 | 414 | 1428 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG200P | 60 | 202 | 590 | 2000 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG250P | 50 | 253 | 490 | 2500 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG300P | 66 | 313 | 657 | 3100 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG350P | 93 | 350 | 924 | 3500 | 3N-380V 50HZ | 9 | TWO STAGE |
BQ SEARIES
YONGXING BOILER GROUP CO.,LTD ------Bonarate burner sales@yxboiler-factory.com | |||||||
BQ SERIES GAS BURNER | |||||||
Burner model | Suitable for boiler (TON/H) | Burner thermal power (KW) | Burner thermal power (CAL/H) | Gas Consume (NM3/H) | Fan power (KW) | Applicable fuel | Adjust Method |
BQ6 | 1 | 175-940 | 151,000-808,000 | 17.5-94 | 1.5 | CITY GAS, NATURAL GAS, LPG GAS gas heat value 36Mj/M3 | Z-Sliding two stage R-Mechanical ratio control E-Electronic proportional control |
BQ10 | 1.5 | 300-1750 | 258,000-1,505,000 | 30-175 | 3 | ||
BQ15 | 2 | 400-2250 | 344,000-1,935,000 | 40-225 | 4 | ||
BQ20 | 3 | 500-3500 | 430,000-3,010,000 | 50-350 | 7.5 | ||
BQ30 | 4 | 500-4080 | 430,000-3,509,000 | 50-408 | 10 | ||
BQ35 | 5 | 900-4780 | 774,000-4,110,000 | 90-478 | 12 | ||
BQ40 | 6 | 700-5400 | 602,000-4,644,000 | 70-540 | 13.5 | ||
BQ55 | 8 | 1000-8150 | 860,000-7,009,000 | 100-815 | 15 | ||
BQ70 | 10 | 1000-10500 | 860,000-9,030,000 | 100-1050 | 22 |
We need to ask you some details for sending you the more suitable quotation
1. what is the application of the burner ?(for food industry ,textile industry, chemical industry or others )
2. what is the capacity per hour do you need?(how many kw ?)
3. which fuel do you want to use for your boiler?(oil or gas,lpg,kerosene and etc ?)
Pls send us effiicent info to get the price soonest.