Asphalt Plant Drying Drum Use Waste Oil /Natural Gas Dual Fuel Burner with two type fuel
Gas Steam Boiler Burner features
Features
1. Two-stage progressive operation
2. After installing the automatic adjuster RWF40 on the control panel, it can conduct proportional adjustment operation.
2. Can adapt to any type of combustion chamber;
3. Air and gas are mixed in the combustion head;
4. Better combustion parameters can be obtained by adjusting combustion air and combustion head;
5. Without removing the burner from the boiler, the mixed unit can be removed directly, which is convenient for maintenance.
6. Independent servo motor regulates air baffle opening.When suspended, the air baffle is automatically closed to reduce heat loss in the furnace
7. Built-in leak detector.
8. Connect the boiler with a hair LAN and an insulating sealing ring
GAS OIL burner burner manufacturers with famous part ,long life time:
SIEMENS CONTROLLER
DUNGS VALVE
DANFOSS NOZZLE
SUNTEC OIL PUMP
BRAHMA/PARKER SOLENOID VALVE
FIDA TRANSFERMA
SIEMENS SERVOMOTOR
INDUSTRIAL LIGHT OIL BURNER DATASHEET FOR REFERENCE
Light Oil Burner YX5-YX350DSG BALTUR DESIGN | ||||||||
MODEL | FUEL COMBUSTION | BUR NER OUTPUT | MAIN SUPPLY | POWER | CONTROL METHOD | |||
KG/HR | KW | |||||||
MIN | MAX | MIN | MAX | W | KV | |||
SINGLE STAGE BURNER | ||||||||
YX5(ST120) | 2 | 5.6 | 24 | 66 | 220V | 110 | 2*5 | S |
YX6 | 2.7 | 6.3 | 24 | 66 | 220V | 110 | 2*5 | S |
YX10 | 5.2 | 10 | 60.5 | 116.6 | 220V | 110 | 2*5 | S |
YX10 | 4.5 | 10 | 54 | 118.6 | 220V | 120 | 2*5 | S |
YX20 | 8 | 20 | 95 | 237 | 220V | 180 | 2*5 | S |
YX14 | 7.5 | 14.5 | 88.5 | 171 | 220V | 150 | 2*5 | S |
YX18 | 7.6 | 18 | 90 | 213 | 220V | 370 | 2*5 | S |
YX26 | 13 | 26 | 154 | 308 | 220V | 370 | 2*5 | S |
YX35 | 15 | 33 | 178 | 391.4 | 220V | 370 | 2*5 | S |
YX34 | 15 | 32 | 178 | 380 | 380V | 370 | 2*5 | S |
YX40 | 20 | 45 | 237 | 534 | 380V | 550 | 2*5 | S |
TWO STAGE BURNER | ||||||||
YX14DSG | 7.5 | 14.5 | 88.5 | 171 | 220V | 150 | 2*5 | T |
YX18DSG | 10.5 | 22 | 124.5 | 261 | 220V | 370 | 2*5 | T |
YX26DSG | 13 | 26 | 154 | 308 | 220V | 370 | 2*5 | T |
YX35DSG | 15 | 33 | 178 | 391.4 | 220V | 370 | 2*5 | T |
YX34DSG | 15 | 32 | 178 | 380 | 380V | 370 | 2*5 | T |
YX40DSG | 20 | 45 | 237 | 534 | 380V | 550 | 2*5 | T |
YX55DSG | 28 | 55 | 332 | 562 | 380V | 1100 | 2*5 | T |
YX75DSG | 35 | 75 | 415 | 880 | 380V | 1500 | 2*5 | T |
YX100DSG | 45 | 100 | 533 | 1185 | 380V | 2200 | 2*5 | T |
YX120DSG | 40 | 140 | 474 | 1660 | 380V | 2200 | 2*5 | T |
YX180DSG | 60 | 180 | 712 | 2135 | 380V | 3000 | 2*5 | T |
YX250DSG | 74 | 270 | 873 | 3185 | 380V | 7500 | 2*5 | T |
YX300DSG | 110 | 325 | 1304 | 3854 | 380V | 7500 | 2*5 | T |
YX350DSG | 115 | 350 | 1346 | 4151 | 380V | 7500 | 2*5 | T |
BY LIGHT DIESEL OIL BURNER RIELLO DESIGN | ||||||||
Burner model | Suitable for boiler (TON/H) | Burner thermal power (KW) | Burner thermal power (MCAL/H) | Oil Consume (KG/H) | Fan power (KW) | Applicable fuel | Adjust Method | |
BY6 | 1 | 300-1186 | 255-1020 | 25-100 | 1.5 | DIESEL OIL KEROSENE OIL 0#diesel 11.86Kwh/kg 1.02x104kcal/h | Z-two stage T-three stage R-Mechanical ratio control | |
BY10 | 1.5 | 600-1900 | 520-1642 | 51-160 | 3 | |||
BY15 | 2 | 770-2750 | 663-2377 | 65-232 | 4 | |||
BY20 | 3 | 890-3100 | 765-2683 | 75-261 | 7.5 | |||
BY30 | 4 | 1100-4100 | 949-3539 | 93-346 | 10 | |||
BY35 | 5 | 1300-5260 | 1122-4549 | 110-444 | 12 | |||
BY40 | 6 | 1150-6100 | 989-5273 | 97-514 | 13.5 | |||
BY55 | 8 | 1900-8750 | 1642-7568 | 160-738 | 15 | |||
BY70 | 10 | 1900-10500 | 1642-9030 | 160-885 | 22 |
Natural gas burner model
NATRUAL GAS BURNER EMAIL: bettysun001@vip.126.com | |||||||
MODEL | GAS COMBUSTION | BURNER OUTPUT | MAIN SUPPLY | Motor | CONTROL METHOD | ||
NM3/HR | KW | ||||||
MIN | MAX | MIN | MAX | KW | |||
SINGLE STAGE CONTROL | |||||||
YXG5 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG6 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG11 | 4.8 | 10 | 48.8 | 99 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG10 | 4.8 | 99 | 48.8 | 99 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG17 | 7 | 17 | 69 | 169 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG20 | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG30 | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG35 | 9 | 35.8 | 90 | 359 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG34 | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | ONE STAGE |
YXG40 | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | ONE STAGE |
YXG50 | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 0.55 | ONE STAGE |
TWO STAGE CONTROL | |||||||
YXG20P | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG30P | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG35P | 9 | 35.8 | 90 | 358 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG34P | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | TWO STAGE |
YXG40P | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | TWO STAGE |
YXG50P | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG60P | 25 | 75 | 248 | 738 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG100P | 28 | 101 | 280 | 995 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG120P | 35 | 121 | 350 | 1200 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG150P | 42 | 144 | 414 | 1428 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG200P | 60 | 202 | 590 | 2000 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG250P | 50 | 253 | 490 | 2500 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG300P | 66 | 313 | 657 | 3100 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG350P | 93 | 350 | 924 | 3500 | 3N-380V 50HZ | 9 | TWO STAGE |