Full Mobile Small Portable Asphalt Plant Asphalt Drum Mix Plant
Product Description
Economical and highly portable alternative to batch asphalt mixing plants
ZAP-CM models are available from 20TPH to 120TPH.
Drying System
- Counter flow drying drum design, drying efficiency is high, save energy.
- Diesel, heavy oil, gas, coal or multi-fuel burners.
- Integrated highly efficient burner on one chassis.
- RAP system and filler system can be optional part.
- Mobile/portable wheeled chassis as optional.
Dust Collecting System
- Bag house dust filter control emission be lower than 20mg/Nm3, eco-friendly.
- Adopt USA Dopont NOMEX filter bags, high temperature resistance and long service life.
- Intelligent temperature and control system.
- Mobile/portable wheeled chassis as optional.
Control system
- Adopt Germany SIEMENS electrical element, working stably even in harsh working environment.
- Adopt Japan ORMON PLC and touch screen, have high data processing capacity, various operation data can be saved real-times.
- Multi-language compatibility, display language can be selected according to the customer’s preference.
Technical Parameters of Mobile Continuous Asphalt Mixing Plant
Items | ZAP-C(M)20 | ZAP-C(M)40 | ZAP-C(M)60 | ZAP-C(M)80 |
Plant Capacity | 20t/h | 40t/h | 60t/h | 80t/h |
Cold Aggregate Feeding System | ||||
Hopper capacity | 3x4m3 | 4x4m3 | 4 x 6.5m3 | 4 x 6.5m3 |
Belt capacity | 40t/h | 60t/h | 80t/h | 100t/h |
Drying System | ||||
Drying drum size | 1000x4500mm | 1200x5000mm | 1500x6500mm | 1500x6500mm |
Drying capacity | 15-25t/h | 40-50t/h | 60-70t/h | 80-100t/h |
Burner (oil) | 40-130kg/h | 70-300kg/h | 100-400kg/h | 60-600kg/h |
Fuel consumption (oil) | 6.5-7kg/t | 6.5-7kg/t | 6.5-7kg/t | 6.5-7kg/t |
Dust Collecting System | ||||
Exhaust Fan power | 5.5kw | 7.5kw | 30kw | 30kw |
Finished Asphalt Silo | 2m3 | 2.5m3 | 4.5m3 | 4.5m3 |
Asphalt Temperature | 130-160 ℃ | 130-160 ℃ | 130-160 ℃ | 130-160 ℃ |
Total Power | -27kw | -57kw | -92kw | -100kw |
Plant capacity is base on standard working condition as followings:
Atmospheric pressure | 760mmHg |
Ambient temperature | 20℃ |
Material passing 40mm mesh | 100% |
Material passing 3mm mesh | 40% |
Material passing 74µm | ≤7% |
Aggregate temperature at discharging end of drum dryer | 160℃ |
Density of aggregate | 1650kg/m3 |
Specific heat of aggregate | 0.21kcal/kg℃ |
Filler content | 5% |
Bitumen content | 5% |
Sand content | ≤40% |
Max.aggregate size | ≤40mm |
Average moisture of cold aggregates | ≤5% |
Diesel calorific value | ≥10500Kcal/kg |
Heavy oil calorific value | ≥9850Kcal/kg |
Nature gas calorific value | ≥8000Kcal/Nm3 |