HQ-TX series 2 phase UPS 6 -10kVA UPS provide 120/240Vac output voltage with output isolation transformer. This powerful online series integrates true double conversion design, DSP technology, and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times. Besides, easy-configurable program via LCD panel enhances the flexibility to meet ever-increasing power demand of IT and networked environment.
Main Features
o Double-conversion with output isolation transformer
o DSP technology guarantees high performance
o Output Power Factor 0.9
o Wide input voltage range (120-275 VAC)
o Active input power factor correction 0.99
o 50Hz/60Hz frequency converter mode
o Eco mode operation for energy saving (ECO)
o Emergency power off function (EPO)
o Generator compatible
o Charger capacity to 6A for long-run models
o SNMP/USB/RS-232 communications
o 3-stage extendable charging design
oReverse polarity and feedback protections
o Maintenance bypass( optional)
o Adjustable battery numbers
MODEL | HQ6KS-TX | HQ6KL-TX | HQ10KS-TX | HQ10KL-TX | |
PHASE | 2-phase in / 2-phase out | ||||
CAPACITY | 6000 VA /5400 W | 10000 VA / 9000 W | |||
INPUT | |||||
Voltage Range | 120-275 VAC (Ph-N) at 50% load ; 180-275 VAC (Ph-N) at 100% load | ||||
Frequency Range | 46~54 Hz or 56~64 Hz auto sensing | ||||
Power Factor | ≧0.99 @ 100% Load | ||||
OUTPUT | |||||
Output Voltage | 120/240 VAC (L-N,L-L) | ||||
AC Voltage Regulation (Batt. Mode) | ± 1% | ||||
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
Current Crest Ratio | 3:1 (max.) | ||||
Harmonic Distortion | ≦ 2 % THD (Linear Load), ≦ 5 % THD (Non-linear Load) | ||||
Transfer Time | AC Mode to Batt. Mode | Zero | |||
Inverter to Bypass | Zero | ||||
Inverter to ECO | < 10ms | ||||
Waveform (Batt. Mode) | Pure Sinewave | ||||
EFFICIENCY | |||||
AC Mode | 90.5% | 91% | |||
Battery Mode | 87% | 88% | |||
ECO Mode | 96% | 96% | |||
BATTERY | |||||
Numbers | 16PCS*12 V / 7 AH | 16PCS*12 V / 9 AH | |||
Typical Recharge Time | 5 hours recover to 90% capacity | 7 hours recover to 90% capacity | |||
Charging Current (Max.) |
1.0 A for standard 6A for long-run model |
1.0 A for standard 6A for long-run model |
|||
Float Charging Voltage | 219 VDC | ||||
INDICATORS | |||||
LCD Display | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding twice every second | ||||
Fault | Continuously sounding | ||||
PHYSICAL | |||||
Machine | Dimension, DxWxH (mm) | 500 x 250 x 860 | 500 x 250 x 620 | 500 x 250 x 860 | 500 x 250 x 620 |
Net Weight (kgs) | 61 | 58 | 72 | 64 | |
Packing | Dimension, DxWxH (mm) | 680 x 380 x 1074 | 680 x360 x834 | 680 x 380 x 1074 | 680 x360 x834 |
Gross Weight (kgs) | 65 | 61.7 | 76 | 68.7 | |
ENVIRONMENT | |||||
Operation Humidity | 0-95 % RH @ 0- 40°C (Non-condensing) | ||||
Noise Level | Less than 60dB @ 1 Meter | ||||
MANAGEMENT | |||||
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser |