Specifications
Brand Name :
HRD/OEM/ODM
Model Number :
PWMA-II 10-40kVA
Certification :
CE, ISO9001
Place of Origin :
Shenzhen Guangdong
MOQ :
10PCS
Price :
2000-10000USD/PCS
Payment Terms :
TT or LC at sight
Supply Ability :
100pcs/ month
Delivery Time :
4 WEEKS after down payment
Packaging Details :
Standard for export
Warranty :
18monts after shipment
Description

Double Conversion 3 Phase Online Surge Protection UPS

Quick Detail:

1) Rated voltage:190/208/220Vac, Line-Line Voltage

2) Type: On-line

3)Use for Servers,Data-center,Telecom

POWERWELL series Online HF UPS 3/3phase 10-40kva transformerless,

(For 190/208/220Vac, Line-Line Voltage);

Perfect Applications:

Internet Servor ,Internet Data Center), Medium-scale network system / computingcenter, bank and securities, business server group, Medium-scale office automation,precision equipment, etc.

Features: complete digital control technology

Fully digital control with two DSPs, all the subsystems are digital controlled including the IGBT rectifier, inverter, charger, discharger.

Excellent electrical properties

True online double conversion instruction offers the safe and effective power protection for various loads, with strong output load capacity;

High input power factor, green and energy-saving

Input end with PFC and input PF of the whole UPS up to 0.99;

Dual AC input source supportable

Allowable AC and bypass 2 input ac source

Strong environmental adaptability

Wide input voltage and frequency range, adaptation to all kinds of climatic

and geographical environment;

Comprehensive protection measures

Surge Protection, short circuit protection, and other protection to ensure the reliability of UPS;

IGBT and SCR adopt the advanced EUPEC power module;

The adoption of advanced technology (IGBT driving technology, IGBT soft over-current shutdown) improves the reliability and safety of inverter.

Intelligent battery management

Adopting the intelligent battery management, prolonging the using life

of battery,decrease the maintaining work;

The max battery charging current can set by end users according to the

battery features, to avoid any damage caused by the big charging current;

Periodic self-test battery, detecting the battery problems timely;

With battery over voltage / current protection, to protect the battery;

Cold start and Mains start Function

Directly start the UPS through battery or start UPS through Mains only.

Superior network monitoring capabilities

Communication port (RS232, USB, and so on) connecting with computer,SNMP card optional,

Easy-maintenance design

a) Adopts the full front maintenance design, reducing the restrictions

on the installation space, and saving the space of computing center;

b)Modular design class, convenient and easy site maintenance;

c) With manual maintain bypass,

d)Battery replacement without disrupting the UPS running;

e) Historical records search function, events up to1,000 items;

Friendly interface

LargeLCD display and LED status indication; Abundant information display of UPS;

Technical Specifications:

Model PWMAII3310S PWMAII3315S PWMAII3320S PWMAII3330S PWMAII3340S
PWMAII3310L PWMAII3315L PWMAII3320L PWMAII3330L PWMAII3340L
Rate Power 10kVA/10kW 15kVA/15kW 20kVA/20kW 30kVA/30kW 40kVA/40kW

Main input

Rate Voltage 190/208/220Vac(L-L) 110/120/127ac(L-N)
Input range

125-265Vac(L-L) for full load;

3P5W (3P+N+PE)

Rate Freq. 50/60Hz
Input PF >0.99
THDi THDi<3% @100% Linear load;THDi<6%@ 100%Non- Linear load;
Freq. range 40-70Hz

Battery/Charger

Rate voltage ±96-120Vdc settable

Model

UPS with internal ,12VDC/7~9Ah,maximum 3*40PCS
UPS for external battery,16-20PCS settable
Charging capacity 20% of UPS capacity

Bypass

Rate voltage 190/208/220Vac(L-L)110/120/1270Vac(L-N)
Voltage range Range: -40%- +25% , Settable, default -20% +15%
Frequency range 50/60Hz Settable ±1Hz ±3Hz ±5Hz

Inverter

Rate voltage 190/208/220/Vac(L-L) 110/120/127Vac(L-N)
Rate Freq. 50/60Hz
Output PF 1.0
Voltage accuracy ±1.0%
Load response <5% (20% - 80% -20% step load)
Recovery time < 20ms (0% - 100% -0% step load)
Output THDu <1% linear load ,<5% non-linear load according to IEC 62040-3
Overload 110%,1 hour 125%,10 mins 150%,1 min >150%,200ms
Frequency accuracy 0.1%
Synchronize window Settable ±0.5Hz-±5Hz default ±3Hz
Slew rate Settable 0.5Hz/S-3Hz/S default 0.5Hz/S
Crest factor 3:1
Phase Accuracy 120°±0.5°

System

Efficiency

Display LED + 7 inch touch LCD
Certification- Safety IEC62040-1, IEC60950-1
Certification- EMS IEC62040-2 IEC61000-4-2(ESD) IEC61000-4-3(RS) IEC61000-4-4 (EFT) IEC61000-4-5 (Surge)
IP degree IP20
Configuration USB, RS232, RS485, Dry contact, Air filter
Option SNMP card, AS400 card, Parallel kit, LBS, Cold start
Environment 0-40 operation -25 ~70 storage 0-95% (Humidity, non-condensing )

Dimension (W*D*H) mm

Internal batteries model 500*864*922
External battery model 250*530*650

Send your message to this supplier
Send Now

Upgrade to Double Conversion 3 Phase Online HF UPS for Stable Power Supply

Ask Latest Price
Brand Name :
HRD/OEM/ODM
Model Number :
PWMA-II 10-40kVA
Certification :
CE, ISO9001
Place of Origin :
Shenzhen Guangdong
MOQ :
10PCS
Price :
2000-10000USD/PCS
Contact Supplier
Upgrade to Double Conversion 3 Phase Online HF UPS for Stable Power Supply
Upgrade to Double Conversion 3 Phase Online HF UPS for Stable Power Supply

Shenzhen HRD SCI&TECH CO.,Ltd

Verified Supplier
17 Years
guangdong, shenzhen
Since 2010
Business Type :
Manufacturer, Exporter
Total Annual :
15,000,000-200,00,000
Employee Number :
300~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement