The LSC board is mainly used to achieve wavelength tunable and to provide OTN interfaces and ESC.
For detailed functions and features, see Table 1.
Function and Feature | Description | ||
---|---|---|---|
Basic function | LSC converts signal as follows: 100GE/OTU4<->1x OTU4 | ||
Client-side service type | 100GE: Ethernet service at a rate of 103.125 Gbit/s. OTU4: OTN service at a rate of 111.81 Gbit/s | ||
OTN function |
| ||
WDM specification | Supports ITU-T G.694.1-compliant DWDM specifications. | ||
Tunable wavelength function | The board can tune the optical signal output on the WDM side within the range of 80 wavelengths in C-band with the channel spacing of 50 GHz. | ||
ESC function | Supported NOTE: When being provisioned with the OTU4 service on the client side, the TN12LSC board supports ESC transparent transmission, but not ESC processing. | ||
PRBS test function | When the client-side service type is OTU4, the PRBS function is supported on the client side. When the client-side service type is 100GE or OTU4, the PRBS function is also supported on the WDM side. | ||
LPT function | Not supported | ||
FEC coding | On the client side: Supports ITU-T G.709-compliant forward error correction (FEC) on the client side, only when the client side service type is OTU4. On the WDM side: The TN12LSC/TN13LSC board supports HFEC and SDFEC . The TN15LSC board supports HFEC and SDFEC2. The TN17LSC board supports SDFEC2. NOTE: Boards that use different FEC modes cannot interconnect with each other. | ||
Alarms and performance events monitoring |
NOTE: Only the TN12LSC board does not support the monitoring of BIP8 bytes on the client side. | ||
Regeneration board | The WDM-side signals from one TN12LSCT01/TN13LSCT01/TN15LSCT01 board can be regenerated by another TN11LTXT01/TN54NS4T01/TN57NS4T01/TN12LTXT01/TN15LTXT01 board. The WDM-side signals from one TN12LSCT11/TN13LSCT11 board can be regenerated by another TN11LTXT11/TN54NS4T11/TN56NS4T11/TN12LTXT11/TN15LTXT11 board. The WDM-side signals from one TN15LSCT31 board can be regenerated by another TN57NS4T31 board. The WDM-side signals from one TN15LSCT51/TN17LSCT51 board can be regenerated by another TN57NS4T51/TN58NS4T51 board. The WDM-side signals from one TN15LSCT52/TN17LSCT52 board can be regenerated by another TN57NS4T52/TN58NS4T52 board. The WDM-side signals from one TN15LSCT53/TN17LSCT53 board can be regenerated by another TN57NS4T53/TN58NS4T53 board. The WDM-side signals from one TN15LSCT61/TN17LSCT61 board can be regenerated by another TN57NS4T61/TN58NS4T61 board. | ||
ALS function | Supports the ALS function on the client side when client services are non-OTN services. | ||
Test frame | Supported only when the client-side service type is 100GE. | ||
Latency measurement | The TN13LSC/TN15LSC/TN17LSCboard supports latency measurement. The bidirectional latency at the ODU4 layer between two OTU boards supporting the latency measurement function can be measured, and the latency data is displayed on the U2000. This function is not supported when the client-side service type is OTU4. | ||
IEEE 1588v2 | Not supported | ||
Physical clock | When receiving 100GE/OTU4 services on the client side, the board supports synchronous Ethernet transparent transmission instead of synchronous Ethernet processing | ||
Optical-layer ASON | Supported | ||
Electrical-layer ASON | Not supported | ||
Protection scheme |
NOTE: When the client-side service is OTU4, the TN12LSC board does not support client-side 1+1 protection. | ||
Loopback | Client side | Inloop | Supported |
Outloop | |||
WDM side | Inloop | Supported | |
Outloop | |||
Protocols or standards compliance | Protocols or standards for transparent transmission (non-performance monitoring) | IEEE 802.3ba | |
Protocols or standards for service processing (performance monitoring) | ITU-T G.805 ITU-T G.806 ITU-T G.709 ITU-T G.872 ITU-T G.7710 ITU-T G.798 ITU-T G.874 ITU-T M.3100 ITU-T G.874.1 ITU-T G.875 ITU-T G.808.1 ITU-T G.841 ITU-T G.8201 ITU-T G.694.1 ITU-T G.8261 ITU-T G.8262 |
Board | WDM-Side Module | Typical Power Consumption (W) | Maximum Power Consumptiona (W) |
---|---|---|---|
TN12LSC | 40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN | 240 | 265 |
55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC)-PIN | 255 | 285 | |
TN13LSC | 40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN | 150 | 160 |
55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC)-PIN | 160 | 170 | |
TN15LSC | 40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN | 145.2 | 158.5 |
150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM-Enhanced)-PIN | 174.6 | 192.6 | |
150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN | 174.6 | 192.6 | |
55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN | 174.6 | 192.6 | |
40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN | 174.6 | 192.6 | |
150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN | 174.6 | 192.6 | |
12000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM-Metro)-PIN | 174.6 | 192.6 | |
TN17LSC | 150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN | 127 | 135 |
55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN | 127 | 135 | |
40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN | 127 | 135 | |
150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN | 127 | 135 | |
12000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM-Metro)-PIN | 127 | 135 | |
120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN | 127 | 135 | |
120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN | 127 | 135 | |
a: The maximum power consumption is the power consumed by the board when it works normally under the highest ambient temperature. |
Cargo will be delivered within 1 day after payment arrived. Tracking Number will be offered once delivery done.
Delivery Options | Estimated Delivery Time |
---|---|
![]() | 3-5 business days |
![]() | 3-5 business days |
![]() | 10-20 business days |
Notice:
Above mentioned information are just for your reference only,we will keep you posted for the tracking delivery schedule.There are two delivery options available for by air and by sea:
Deliver to port:
Uonel is responsible for transporting goods to port. All subsequent customs and transportation fees are the
responsibility of the buyer. Uonel will recommend trustworthy local freight forwarders to you.Uonel can facilitate the progress under buyer's permission and at buyer's expense.
Deliver to door:
Uonel will quote all destination charge prior once we have confirmed order.
Uonel is responsible for transporting goods to door after you have made the payment.
100% Low Price Guarantee:
Uonel provides high-quality products at low wholesale prices
100% Quality Assurance:
All items are ORIGINAL NEW and GENUINE only.
Free Technical Support:
Our FREE Huawei Expert Consultancy Support is over the phone, by chat, by email or by login remotely.
100% Money Back Guarantee:
You can contact our customer service team to exchange or return any product that you bought from us.
Flexible Secure Payment & Shipment:
Verified authorization: Mcafee Secure, VeriSign Secured
Return Material Authorization (RMA) Process
Standard Hardware Warranty Policy:
Original new sealed Huawei product: 1 Year
The Support Contacts:
If your Huawei products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.
Uonel is one of the biggest Huawei Network Hardware distributor in china, founded in 2008. We are a global provider of netwotking products with more than 5000 customers.
We provide original new Huawei Routers,Switches,Firewalls,Wireless APs & controllers,OLTs,GPON modems,optical transceivers.Our company have more than $5million Huawei products in stock.
Most of our technical engineers had work exprience in Huawei company,we can provide network design&planning,configration,troubleshooting,maintenance and training service in world wide.