DN10-3000mm Electromagnetic Water Flow Meter Integrated Type
Electromagnetic Water Flow Meter is used to measure the electromagnetic flow of conductive liquid, solid-liquid two-phase body and other fluids in a wide range of working conditions.
Electromagnetic Water Flow Meter Parameters
Items | VMG600 Electromagnetic Water Flow Meter |
Nominal diameter | DN10-3000mm |
Pressure | 0.6~4.0MPa ( Special pressure customizable) |
Flow range | 0.1~15m/s |
Structural style | Integrated type , Split type , Insert type, Battery powered type |
Protection Class | IP65, IP68 optional |
Medium Conductivity | ≥20μs/cm |
Liner Material | PU, PTFE, CR, FPM, F46, PFA |
Accuracy | Indicated value ±0.5%, Optional values ±0.3% |
Electrode material | HB, HC, WC, 316L, Ti, Ta, Pt |
Connection | Flange Clamp Thread |
Signal output | Pulse / 4~20mA / RS485 / HART/Modbus |
Electromagnetic Water Flow Meter Feature
1. The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity.
2. The series is nominally DN3 – DN3000 (Below DN15, kindly contact us for more details).
3. There are many options for sensor liners and electrode materials.
4. The converter adopts novel excitation method, low power consumption, stable zero point and high accuracy.
Flow range up to 1500: 1.
5. The converter can be integrated with the sensor or separate.
6. The converter adopts 16-bit high-performance microprocessor, 2x16LCD display, convenient parameter setting and reliable programming.
7. The converter uses surface mount technology (SMT), with self-test and self-diagnosis functions.
8. The rubber and polyurethane lining sensor are intrinsically immersed structure.


How to order?
(A) How to choose Lining material?
Lining Material | Applications |
PTFE | Strong corrosive mediums such as strong acid and alkali-20 ~ 120℃ |
F46 | The same as PTFEApplicable in medium of low abrasion -40 ~ 160℃ |
PFA | The same as F46. Applicable in state of load pressure-40 ~ 160℃ |
Neoprene | Water, sewage and slurry, mineral serosity of low abrasion-20 ~ 60℃ |
PU | Applicable in mineral serosity, slurry and coal slurry of high abrasion-20 ~ 60℃ |
(B) How to choose Electrode material?
Electrode Material | Applications |
SS316L | Applicable in water, sewage and corrosive mediums. |
Tungsten carbide | Applicable in mediums of no corrosive and low abrasion. |
Hastelloy B (HB) | Having strong resistance to hydrochloric acid of any consistance. |
Hastelloy C (HC) | Resistant to oxidable acid such as nitric acid, mixed acid etc. |
Titanium | Seawater, and kinds of chloride, hypochlorite salt, oxidable acid etc. |
Tantalum (Ta) | Hydrofluoric acid, fuming sulfuric acid, alkali remaining chemicals etc. |
Platinum-iridium | Chemical mediums except for aqua fortis, ammonium salt. |