Specifications
Brand Name :
Meilong Tube
Model Number :
3 / 8 '' OD x 0.049 '' WT
Certification :
ISO9001 : 2015
Place of Origin :
China
MOQ :
1000 meters
Payment Terms :
L/C, T/T
Supply Ability :
100 metric tons per month (including duplex steel tubing, nickel alloy tubing)
Delivery Time :
7 days
Packaging Details :
Level wound coiled on spools/drums, and packed in wooden cases
Alloy :
TP316L, UNS S31603
Surface :
Clean and bright
Condition :
Cold worked
Properties :
Enhanced tensile and yield
Feature :
High pressure tubing
Application :
Down hole temperature measuring
Standard :
ASTM A269
Size :
Tight dimensional tolerances
Inside :
Temperature measuring cable
Design Capability :
Customized
Description

316L Stainless Steel Tubing Encapsulated Cable for Downhole Applications in Oil Wells

Tubing Encapsulated Cable (TEC)

TEC uses welded stainless steel and nickel alloy tubing to protect electrical and optical components from the pressure and corrosive effects of the downhole environment. Polymeric encapsulation provides additional mechanical protection.

A wide selection of copper and fiber components from Meilong Tube allow production of the industry’s most sophisticated instrumentation cables. Since first introducing TEC for the oil and gas industry in 2015, Meilong Tube has continually improved and optimized this product for new generations of downhole gauges and tools for increasingly hotter and deeper wells.

TEC configurations are available with an almost infinite combination of components in splice-free custom lengths.

Standard encapsulation sizes (11 mm x 11 mm square) are available to meet almost any downhole requirements.

Composite cables utilizing various combinations of electrical and optical components are available to match specific downhole needs.

Typical Constructions

18 AWG Single Conductor Incoloy 825 Tube Square Encapsulated

SS316L Encapsulated Cable UNS S31603 Tubing Encapsulated Conductor For Downhole

A) 18 AWG (7 x 0.39 mm) tinned copper

O.D. 0.046 in (1.16 mm) nominal

B) FEP insulation

O.D. 0.098 in (2.49 mm) nominal

C) Red polypropylene filler

O.D. 0.180 in (4.57 mm) nominal

D) Alloy 825 tube

Wall thickness 0.035 in (0.89 mm) nominal

O.D. 0.250 in (6.35 mm) nominal

E) Yellow square profile polypropylene

0.433 in (11 mm) square

5 AWG Single Conductor Stainless 316L Tube Encapsulated

SS316L Encapsulated Cable UNS S31603 Tubing Encapsulated Conductor For Downhole

A) 5 AWG (single conductor) copper

O.D. 0.181 in (4.6 mm) nominal

B) PFA insulation

O.D. 0.228 in (5.8 mm) nominal

C) PFA insulation

O.D. 0.276 in (7.0 mm) nominal

D) Stainless steel 316 tube

Wall thickness 0.035 in (0.89 mm) nominal

O.D. 0.375 in (9.53 mm) nominal

Tubing Options

TEC is selected based on well conditions such as pressure, temperature and corrosiveness of the well fluid. The tubing is composed of an alloy matched to the application. It is then longitudinally welded, eddy current tested and drawn to finished size. Complete test data is available for every tube.

- Stainless steel 316L

- Duplex 2205

- Super Duplex 2507

- Incoloy 825

Mechanical Characteristics for Alloy TEC, Cold Worked

Diameter Wall Thickness

Stainless 316L

Minimum Collapse

Incoloy 825

Minimum Collapse

Minimum Bend Radius*
inches inches psi psi inches
0.125 (1/8) 0.022 23,882 25,209 0.75
0.250 (1/4) 0.028 16,371 17,281 1.50
0.250 (1/4) 0.035 19,688 20,781 1.50
0.250 (1/4) 0.049 26,173 27,627 1.50
0.375 (3/8) 0.035 13,783 14,549 2.25
0.375 (3/8) 0.049 18,739 19,780 2.25

Calculations based on minimum yield strength of 120,000 psi.

All TEC tubing is oversized welded and drawn.

Tubing can be custom printed with a variety of data including part number, serial number, sequential length and purchase order number.

*The bending radius indicated is in a static condition after final training at the termination. All bending must be performed using a tubing bender to ensure that the bending radius is uniform. While deploying into or out of the well, the minimum bending radius should be as large as possible.

Electrical Components

TEC Style TEC 100 TEC 150 TEC 175 TEC 200 TEC 250
Temperature Range -10 to 100°C -10 to 150°C -100 to 175°C -100 to 200°C -100 to 250°C
Filler PP PP FEP FEP PFA
Insulation PP FEP FEP FEP PFA

Maximum Electrical Conductor Resistance @ 20°C (68 °F)

Conductor

Conductor

O.D.

Conductor

O.D.

Solid Bare Copper 7 Strands Bare Copper
AWG inches mm Ohms / kft Ohms / m Ohms / kft Ohms / m
18 0.0403 1.02 6.52 21.4 6.66 21.8
17 0.0453 1.15 5.15 16.9 5.27 17.3
16 0.0508 1.29 4.10 13.5 4.18 13.7
15 0.0571 1.45 3.24 10.6 3.31 10.9
14 0.0641 1.63 2.57 8.45 2.62 8.62
13 0.0720 1.83 2.04 6.69 2.08 6.82
12 0.0808 2.05 1.62 5.31 1.65 5.43
11 0.0907 2.30 1.29 4.22 1.32 4.30
10 0.102 2.59 1.019 3.34 1.039 3.41
9 0.114 2.90 0.808 2.65 0.825 2.71
8 0.128 3.25 0.641 2.10 0.654 2.14

Send your message to this supplier
Send Now

SS316L Encapsulated Cable UNS S31603 Tubing Encapsulated Conductor For Downhole

Ask Latest Price
Brand Name :
Meilong Tube
Model Number :
3 / 8 '' OD x 0.049 '' WT
Certification :
ISO9001 : 2015
Place of Origin :
China
MOQ :
1000 meters
Payment Terms :
L/C, T/T
Contact Supplier
SS316L Encapsulated Cable UNS S31603 Tubing Encapsulated Conductor For Downhole
SS316L Encapsulated Cable UNS S31603 Tubing Encapsulated Conductor For Downhole
SS316L Encapsulated Cable UNS S31603 Tubing Encapsulated Conductor For Downhole

Suzhou Meilong Tube Co., Ltd.

Verified Supplier
3 Years
jiangsu
Since 2009
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
13.4 million-14.9 million
Employee Number :
90~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement