The High Pressure Steam Sterilizer is an essential product in the field of Dental Sterilization Machines, offering efficient and reliable sterilization for various medical and dental instruments. This Hydrogen Peroxide Sterilizer is designed to provide a safe and effective sterilization process using high-pressure steam.
Before using the Automatic Autoclave Sterilizer, it is crucial to follow the necessary Preparation Steps to ensure optimal performance and safety. Users should first verify the water level in the sterilizer, ensuring it is adequate for the sterilization process. Checking the integrity of the safety valve is also vital to prevent any pressure build-up inside the chamber. Additionally, load items into the chamber without overcrowding to allow for proper steam circulation and thorough sterilization.
When operating the High Pressure Steam Sterilizer, users should follow the designated Operating Procedures to achieve successful sterilization results. The process typically involves three main phases: Preparation, Sterilization Phase, and Completion. During the Preparation phase, users set the desired sterilization parameters and ensure all instruments are properly loaded. The Sterilization Phase involves raising the temperature and pressure inside the sealed chamber to effectively eliminate any pathogens. Finally, the Completion phase signals the end of the sterilization cycle, and users can safely remove the sterilized items from the autoclave.
Key Components of the High Pressure Steam Sterilizer include a sealed chamber that maintains the steam pressure, a pressure gauge to monitor the internal pressure, a safety valve that releases excess pressure to prevent accidents, an exhaust valve to remove air from the chamber before sterilization, and heating elements that generate steam for the sterilization process. These components work together seamlessly to ensure efficient and reliable sterilization of instruments.
Proper maintenance of the High Pressure Steam Sterilizer is essential to prolong its lifespan and maintain its effectiveness. Users should regularly inspect the safety valves to ensure they are functioning correctly and can release excess pressure when needed. Checking the seals of the chamber and exhaust lines is also crucial to prevent steam leakage during the sterilization process. Additionally, users should remove any mineral deposits that may accumulate inside the chamber post-use to prevent clogging and ensure optimal performance.
Sterilization Phase Steps | Heat to generate steam, maintain target pressure for 15–30 minutes |
Preparation Steps | Verify water level, safety valve integrity, load items without overcrowding |
Pre-vacuum Type Features | Removes air before sterilization to enhance steam penetration |
Vertical Type Features | Larger capacity, designed for hospitals or bulk sterilization |
Suitable Materials | Heat-resistant materials such as culture media, glassware, and surgical instruments |
Operating Procedures | Preparation, Sterilization Phase, Completion |
Typical Applications | Laboratories, Medical Settings, Food Industry |
Completion Steps | Allow natural cooling, open exhaust valve and lid cautiously |
Principles and Functions | Autoclaves use high-temperature, high-pressure saturated steam to denature microbial proteins, achieving sterilization |
Safety Protocols | Operator training is mandatory, never open the lid before pressure release |
ZJNF High Pressure Steam Sterilizer is a versatile product suitable for a wide range of Product Application Occasions and Scenarios. Its portable type features make it ideal for routine laboratory use, allowing for efficient sterilization of heat-resistant materials such as culture media, glassware, and surgical instruments.
With its sealed chamber and key components including a pressure gauge, safety valve, exhaust valve, and heating elements, this sterilizer from China's ZJNF brand ensures thorough sterilization processes. The completion steps are easy to follow, requiring users to allow natural cooling, and open the exhaust valve and lid cautiously.
For liquid sterilization, this sterilizer offers a useful tip to vent pressure gradually, ensuring proper sterilization of liquids. This feature is particularly useful for scenarios where liquid sterilization is required, such as in Hospital Air Sterilization applications.
The ZJNF High Pressure Steam Sterilizer has a minimum order quantity of 1 and accepts payment terms including L/C, T/T, and Western Union. Delivery time is 20 days, and the packaging details include plywood for safe transportation.
Overall, the ZJNF High Pressure Steam Sterilizer is a reliable product that can be used in various scenarios including Hand Held Steam Cleaners applications, Hospital Air Sterilization, and Deep UV Sterilizer processes. Its compact and lightweight design makes it a convenient choice for laboratories and healthcare facilities.
The Product Technical Support and Services for the High Pressure Steam Sterilizer include:
- Installation assistance
- User training and education
- Troubleshooting guidance
- Maintenance support
- Repair services
Product Packaging:
The High Pressure Steam Sterilizer is carefully packaged to ensure safe delivery. It is securely wrapped in protective materials to prevent any damage during transit. The product is enclosed in a sturdy cardboard box with proper labeling for easy identification.
Shipping:
Orders for the High Pressure Steam Sterilizer are processed promptly to ensure fast delivery. We partner with reliable shipping carriers to transport the product to your designated address. You will receive a tracking number to monitor the status of your delivery. Please ensure someone is available to receive the package upon arrival.
Q: What is the brand name of the High Pressure Steam Sterilizer?
A: The brand name of the High Pressure Steam Sterilizer is ZJNF.
Q: Where is the High Pressure Steam Sterilizer manufactured?
A: The High Pressure Steam Sterilizer is manufactured in China.
Q: What is the minimum order quantity for the High Pressure Steam Sterilizer?
A: The minimum order quantity for the High Pressure Steam Sterilizer is 1.
Q: What are the payment terms accepted for purchasing the High Pressure Steam Sterilizer?
A: The accepted payment terms for purchasing the High Pressure Steam Sterilizer are L/C, T/T, and Western Union.
Q: What is the delivery time for the High Pressure Steam Sterilizer?
A: The delivery time for the High Pressure Steam Sterilizer is 20 days.
Q: How is the High Pressure Steam Sterilizer packaged for delivery?
A: The High Pressure Steam Sterilizer is packaged in plywood for delivery.