IEC 60065 clause 7.1 Hot Winding Resistance Meter RXDC-3/ RXDC-3A
Standard:Conforms to IEC 60065 clause 7.1, IEC60950, IEC60335-1 clause 11 Household and similar electrical appliances-safety-Part 1:General requirements.
Application:Used for the winding temperature measurement of various household appliances and completed products(such as air conditioners, refrigerators, electric fans, washing machines, etc.)and other small power motor and transformers.
Test sample:Household appliances.
Feature:Single channel or dual channel can be selected.
Parameters:
1.Measuring range:0.5~20~200~2000Ω
2. Measurement Accuracy:cold state ±0·1%READ+0·1%FS, thermal state ±0·15%READ+0·15%FS
3. Ambient temperature:Measuring range 0~ 50℃,Measurement Accuracy ± 0·5℃
4. Temperature Rise:Calculated according to the formula rise
5. Thermal resistance response time:<30 seconds
6. Experimental time:Maximum 99 hours 59 minutes 59 seconds,Accuracy ±0·1%
7. Winding temperature coefficient can be set to 0 ~ 999.9, all set parameters latched when power failure.
8. Instrument standard equipped serial port, can communicate with the computer serial
9. Testing software content: Record the temperature change data, display temperature curves, check printing.
10. Optional mini-printer, can print multi-channel temperature data timing, the print measurement time interval can be set by the user.
11. Standard equipped 25-pin parallel printer port, you can connect the printer directly to print test data; multi-channel temperature data can be regularly print, the measurement time interval can be set by the user.
12. Power supply:AC220V ±10%,50Hz /60Hz, Total power consumption<15W
13. Operating environment:Operating Temperature 25℃±15℃; Humidity 60%±30%