IEC60335 / 4000cm³ Cable Testing Equipment Oxygen Bomb - Air Bomb Aging Tester
IEC60335-1 clause 22.32:
The part is suspended freely in an oxygen bomb, the effective capacity of the bomb being at least 10 times the volume of the part. The bomb is filled with oxygen not less than 97 % pure, to a pressure of 2,1 MPa ± 0,07 MPa and maintained at a temperature of 70 °C ± 1 °C.
NOTE The use of the oxygen bomb presents some danger unless handled with care. Precautions should be taken to avoid the risk of explosion due to sudden oxidation. Cable Testing Equipment
The part is kept in the bomb for 96 h. It is then removed from the bomb and left at room temperature out of direct sunlight for at least 16 h.
The part is then examined and shall show no crack visible to the naked eye.
Standard: IEC60335-2-6 clause 22, IEC60335-2-9 clause 22,Clause 22.32 of IEC 60335-1 Household and similar electrical appliances – Safety – Part 1: General requirements, IEC 60811-1-1 sub clause 9.1 and IEC 60811-1-2 sub clause 8.3 and etc.
Application: It is used to process the aging test for the electric wire, the insulation layer and sheath of the rubber( plastic,artificial leather) as well as other high polymer materials under the action of required pressure and temperature in the medium of oxygen and compressed air.
Test sample: Wires, cables, rubber (plastic, leather) insulation layer and sheath, as well as other polymer materials. Cable Testing Equipment
Feature: The device adopts inside and outside dual-chamber structure, the samples are suspended in an oxygen tube, filling with oxygen purity ≥ 97%, make the pressure up to 2.1 ± 0.07 MPa and maintain the temperature at 70 ° ± 1 ° C, then process aging test for 96 hours in this state. Cable Testing Equipment
Parameters:
Input Power | 230V/50HZ |
Maximum Operating Pressure | 4MP |
Secure Burst Pressure | 2.7~3.3MP |
Temperature-controlled range | indoor temperature~200℃ |
Outer Chamber Dimensions | 820mm×420mm×670mm |
Inside Chamber Dimensions | Diameter 123×Height 337mm |
Inside Chamber Volume | 4000cm³ |
Heating Power | 2.5KW |
Temperature Alarm | 0~200℃ Adjustable |
Temperature deviation | ±0.5℃ |
Temperature Control | Intelligent control |
Temperature Display | Thermometer display |
Material | Inside chamber is made of stainless steel and outer chamber is made of electrostatic spraying steel plate |