UL982 Probe For Uninsulated Live Parts And Film-Coated Wire Length 101.6mm Diameter 19.1
Description in UL982 2009 Clause 58.9.2:
In the enclosure of an appliance other than as described in 58.9.1, an opening which does not permit entrance of a 3/4 inch-diameter (19 mm) rod is acceptable if:
a) A probe as illustrated in Figure 58.6 cannot be made to touch any uninsulated live part or moving part capable of causing injury when inserted through the opening, and Test Finger Probe
b) A probe as illustrated in Figure 58.7 cannot be made to touch magnet wire when inserted through the opening.
Exception: If unacceptable results are obtained using the probe illustrated in Figure 58.6 and 58.7, the probe illustrated in Figure 7.1 may be used to determine that the part is not more accessible than with a sample prior to conditioning. Test Finger Probe
Standard:UL507-2006(PA135A)Fig 9.1, UL749 Fig 1, UL982 Fig 58.6 and UL1278 Fig 8.1(PA130A).
UL398 Fig 8.2(PA170B),UL507(PA170D),UL749 Fig 2,UL982 Fig 58.7 and UL1278 Fig 8.2(PA140A).
Application:It is used for the performance of the electrical equipment enclosure preventing electric shock, and the testing of coating lines of the enamel (i.e., transformers and inductors).
Test sample:Easily accessible enclosure live parts or mechanical parts, transformers and inductors.
Feature:Nylon handle + probe, it is manufactured according to the standard figure. Test Finger Probe
Parameters:
Name | Value | Value |
Length 1 | 101.60mm | 101.60mm |
Length 2 | 14.3mm | - |
Radius | 4.8mm | 6.4mm |
Diameter 1 | 12.7mm | 12.7mm |
Diameter 2 | 19.1mm | 19.1mm |