Descriptions
13.8V/2A 12V/2A Ac Dc Power Supply Access control system power supply with battery charger back up function.
Features
Specifications
MODEL | ACS-U40D13.8+13.8 | |||
OUTPUT | Ouput Number | V1 (mains AC power) | V2 (battery power) | |
DC Output | 13.8Vdc | 13.8V | ||
Rated Current | 2A | 0.2A-0.4A(constant current limit) | ||
Current Range Note 1 | 0.05A – 2.0 | / | ||
Ripple and Noise Note 2 | 0~60℃ | <100mV | / | |
-20~0℃ | <200mV | / | ||
Voltage Accuracy | ±3.0% | / | ||
Line Regulation | ±1.0% | / | ||
Load Regulation | ±2.0% | / | ||
Voltage Adjustable Range | 13.0-13.8Vdc | |||
Set-up Time | <1.0S (230Vac input, Full load),<2.0S(115Vac input,Full load) | |||
Hold up Time | >20mS(230Vac input, Full load),>10mS(115Vac input,Full load) | |||
Temperature Coefficient | ±1.0%/℃ | |||
Overshoot &Undershoot | <5.0% | |||
Battery current during deep discharge | <1mA | |||
INPUT | Voltage Range | 90Vac-264Vac (Rated:100Vac-240Vac) | ||
Frequency Range | 47Hz-63Hz | |||
Efficiency ( Typical) | 75%@230Vac, 72%@115Vac | |||
AC Current (max.) | 1.2A | |||
Inrush Current (Typical) | <50A@230Vac ;<30A@115Vac Cold start | |||
Leakage Current | Input—Output: ≤0.25mA Input—PG: ≤3.5mA | |||
PROTECTION | Deep discharge cut off | 9Vdc-10Vdc | ||
Over Current | V1:2.5A-4.0A, hiccup mode,auto recovery | |||
Over Voltage | V1: 110%-150%, constant voltage | |||
Shorted Circuit | Long-time; auto recovery | |||
Battery reverse polarity | Self auto-recovery fuse
. | |||
SIGNAL | AC OK / Fail signal | AC OK: Sig=0(0-1Vdc) Current<=50mA(this depends on customers control unit) AC Fail: Sig=1(voltage depends on customers control unit) | ||
Status Indication | Green LED(LED1) | AC ON,the device is being supplied from the SMPS. | ||
RED LED(LED2) | AC OFF,the device is being supplied from the battery backup device | |||
ENVIRONMENT | Operating.Temp.& Hum. | -20℃~60℃; 20%~90%RH No condensing (refer to the derating curve) | ||
Storage Temp. & Hum. | -40℃~80℃; 10%~95%RH No condensing | |||
SAFETY &EMC (Note 3) | Safety Standards | UL60950-1; EN60950-1:2006;LVD 73/23/EEC | ||
EMC | Compliance to EN55022(CISPR22)Class B EN55024; FCC 15.107, FCC15.109,EMC 2004/108/EC | |||
Isolation Resistance | ≥100M ohms | |||
OTHERS | MTBF (MIL-HDBK-217F) | More than 200,000Hrs (25℃, Full load) | ||
Dimension (L*W*H) | 173.4×60×57.1mm | |||
Cooling method | Cooling by free air convection
| |||
NOTE |
| |||
Withstand Voltage | Primary-Secondary:3.0KVac;≤10mA.Primary-PG:1.5KVac;≤10mA.Secondary-PG:500VDC;≤10mA. |