Factory direct sale EI19 1:1 audio isolation transformer
Classified by working frequency:
Power frequency (low frequency) transformer, its working frequency is 50HZ or 60HZ;
Intermediate frequency transformer, its working frequency is 400~1000HZ;
Audio transformer, its working frequency is 20HZ~20KHZ
Super audio transformer, its working frequency is above 20KHZ, generally not more than 100KHZ
High frequency transformer, its working frequency is above 20HZ~100KHZ.
; according to the insulation level, it can be divided into A-class insulation transformers, E-class insulation transformers, B-class insulation transformers, and F-class insulation transformers. Transformers, H-class insulation transformers, etc.
Classification
1. Classified by working frequency:
Power frequency (low frequency) transformer, its working frequency is 50HZ or 60HZ;
Intermediate frequency transformer, its working frequency is 400~1000HZ;
Audio transformer, its working frequency is 20HZ~20KHZ
Super audio transformer, its working frequency is above 20KHZ, generally not more than 100KHZ
High frequency transformer, its working frequency is above 20HZ~100KHZ.
2. Classification by use:
Power transformers, audio transformers, pulse transformers, switching power transformers, special transformers
3. According to the iron core structure classification:
Shell-type transformers, such as EI type insert core transformers, F type;
Core-type transformers, such as R-type transformers;
Toroidal Transformer.
4. According to the number of phases:
Single-phase transformers, three-phase transformers, multi-cabin transformers.
5. According to the moisture-proof method:
Open transformers, sealed transformers, resin-encapsulated transformers.
6. Other ways to classify:
For example, according to the transformer coefficient, it can be boosted and stepped down; according to the number of groups, it can be divided into double-winding and multi-winding; according to the insulation level, it can be divided into A-class insulation transformers, E-class insulation transformers, B-class insulation transformers, and F-class insulation transformers. Transformers, H-class insulation transformers, etc.
GENREAL SPECIFICATION:
PATRNUMBER: EI19 soft feet 2+3
STORAGE TEMP RANGE: -45℃ TO +125℃
OPERATING TEMP RANGE: -40℃ TO +85℃
RELATIVE HUMITY RANGE: 5% TO 95%
ELECTRICAL SPECIFICATION:(25℃)
TEST | TURNS RATIO | L(1-3) 1KHZ 0.3V 25% | L(4-5) 1KHZ 0.3V 25% | DCR(1-3) 15% | DCR(4-5) 15% | HI-POT 1mA,60S |
EI1901 | 1:1 | 1.2H | 1.2H | 22Ω | 28Ω | 500V |
EI1902 | 1:1 | 1.9H | 1.9H | 270Ω | 336Ω | 500V |
EI1903 | 1:1 | 585mH | 585mH | 60Ω | 75Ω | 500V |
EI1904 | 1:5 | 2.9H | 150mH | 340Ω | 12.5Ω | 500V |
EI1905 | 1:11 | 266mH | 17H | 71Ω | 1.58KΩ | 500V |
SCHEMATIC:
OUTOINE DIMENSION:UNIT:(mm)