Specifications
Model Number :
MLF
Place of Origin :
China
MOQ :
1pc
Price :
Negotiation
Payment Terms :
T/T
Supply Ability :
500pcs per month
Delivery Time :
7-10 working days
Packaging Details :
In Carton or Wooden Box
Product Name :
Electromagnetic Flow Meter
Pipeline Diameter :
DN15-DN2000
Accuracy :
0.2% or 0.5%
Flange :
GB/ANSI/JIS/BS/Others
Output :
Hart, RS485, Profibus, 4-20mA, Frequency, Pulse
Velocity Range :
0.3~10m/s
Description

OEM Electromagnetic Flow Meter Sensor for Conductive Liquid

1. Introduction

MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction, and is composed of sensors and converters. Used to measure the conductivity of liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water and raw water conductivity is about 100 ~ 500μs/cm), and it can also be used to measure acid, alkali, brine, pulp or pulp and other media. However, these media cannot contain a large amount of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument for measuring liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries.

2. Features

MLF electromagnetic flowmeter is explosion-proof design.

Low conductivity measurement function.

There are nine languages(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

It has self-regulation function and self-test.

Different outputs are optional: Hart, RS485, Profibus, 4-20mA, frequency, pulse.

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

4. Selection of Electrode Materials

Electrode Material Main Performance
316L

Good corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on.

Hb

Good resistance to all concentrations below the boiling point of hydrochloric acid, but also resistant to non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.

Hc

Corrosion of oxidizing acids, such as nitric acid, mixed acids. A mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3,Q3, and some other oxidants, such as a mixture of hypochlorite solution and seawater above normal temperature.

Ti

Resistant to corrosion of seawater, various chlorides, hypochlorite, oxidizing acids (including fuming nitric acid), organic acids or bases, but not pure reductive acids (e.g., sulfuric acid, hydrochloric acid) etc. but if the acid contains oxidants (such as nitric acid, Fe3,Q3), the corrosion resistance will decrease.

Ta Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-Ir Have good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten Carbide For pulp and sewage, good resistance to solid particle interference.

5. Dimensional Sketches

a. Dimension of Converter

Conductive Liquid DN15 ANSI Electromagnetic Flow Meter

Divided Type

Conductive Liquid DN15 ANSI Electromagnetic Flow Meter

Integrated Type

Conductive Liquid DN15 ANSI Electromagnetic Flow Meter

Battery Powered Type

b. Dimension of Sensor

Conductive Liquid DN15 ANSI Electromagnetic Flow Meter

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

6. Instrument Detection & Maintenance

Electromagnetic flowmeter has self-diagnosis function. In addition to power supply and hardware circuit faults, the system also alarms other faults in general use. These messages give corresponding tips in the lower right corner of the screen.

1 Maintenance and repair

A) the sensor installation site shall meet the requirements of section 4, and please keep the housing clean and tidy;

B) The transmitter shall be placed in a clean, ventilated and dry place;

C) it needs to be checked every two years. for high-precision users, the instrument needs to be submitted for review.

2 Transportation and storage

A) the instrument must be packed before transportation and handled with care.

B) The storage place must be dry and ventilated to avoid corrosive gas erosion, and the ambient temperature should not be too low or too high;

C) the storage time should not exceed three years.

3. Unpacking inspection

A) the package cannot be opened with a heavy hammer, so be careful not to damage the instrument.

B) carefully check the contents according to the packing list.

7. Product Photos

Conductive Liquid DN15 ANSI Electromagnetic Flow Meter

Send your message to this supplier
Send Now

Conductive Liquid DN15 ANSI Electromagnetic Flow Meter

Ask Latest Price
Model Number :
MLF
Place of Origin :
China
MOQ :
1pc
Price :
Negotiation
Payment Terms :
T/T
Supply Ability :
500pcs per month
Contact Supplier
Conductive Liquid DN15 ANSI Electromagnetic Flow Meter
Conductive Liquid DN15 ANSI Electromagnetic Flow Meter

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Site Member
6 Years
shanghai, shanghai
Since 2019
Business Type :
Manufacturer, Exporter
Total Annual :
$1000000-$2000000
Employee Number :
>50
Certification Level :
Site Member
Contact Supplier
Submit Requirement