Stable Diffusion Silicon Gauge Pressure Transmitter 4 - 20mA Hit - Resistant Capacitance
1. Introduction
ML2000W series diffusion silicon pressure transmitter adopts the advanced transducer as sensitive element. It applies shielding and eliminating process of new hit-resistant capacitance, RF, over current and strong voltage signal. The subsequent circuit has higher stability and capacity of resisting disturbance because the peripheral circuit layout and component selection are more reasonable than American TI (BB) company operational amplifier.
2.Technical Parameter
Accuracy | ±0.2% or ±0.1% |
Measuring Range | -0.1KPa~0~100KPa~40MPa (Max. 100MPa) |
Ambient Temperature | -20~85℃ |
Medium Temperature | -20~90℃ |
Storage Temperature | -40~85℃ |
Relative Humidity | <95% |
Output | 4-20mA |
Power Supply | 24VDC or 12VDC |
Stability | Better than 0.1%FS Per Year |
Overload Limit | 150%~300% |
① Power supply non polar connection(Only analog circuit, 24VDC power supply)
② Field or Outside lightning prevention design
3. Structure & Material
Diaphragm | 316L Stainless Steel |
Process Connection | M20x1.5 Male Thread; Stainless Steel |
Sealing | Fluorine Rubber |
Shell & Surface | Aluminum; Epoxy |
Installation Location | No Special Requirements |
4. Configuration
Type | Specification Code | Illustration |
ML2¨¨¨W | --------------------------------- | Diffused Silicon Pressure Transmitter |
Transducer | 0-------------------------------- | Diffused Silicon Transducer |
Accuracy | 8-------------------------------- | ±0.2% |
5-------------------------------- | ±0.1% | |
Output | 8-------------------------------- | 4-20mA |
1-------------------------------- | 4-20mA, HART | |
W-------------------------------- | ||
Contact Medium Mode | F-------------------------------- | Remote Transmission Flange Installation Type |
G-------------------------------- | High Temperature Heat Radiation Type(0-200℃) | |
P-------------------------------- | Flat Diaghragm Contact Type | |
L-------------------------------- | Thread Connection * | |
Connection Mode | 2-------------------------------- | Flange Connection (Note 1) |
3-------------------------------- | M20x1.5 * | |
4-------------------------------- | Other Thread Connection (Note 2) | |
Measuring Range | 1-------------------------------- | 0-5~35KPa |
2-------------------------------- | 0-35~100KPa | |
3-------------------------------- | 0-50~200KPa | |
4-------------------------------- | 0-100~350KPa | |
5-------------------------------- | 0-200~700KPa | |
6-------------------------------- | 0-0.5~2.1MPa | |
7-------------------------------- | 0-1~3.5MPa | |
8-------------------------------- | 0-3~7MPa | |
9-------------------------------- | 0-7~21MPa | |
0-------------------------------- | 0-15~40MPa | |
Y-------------------------------- | Specific Range (Note 3) | |
Display Header | D-------------------------------- | Multiple Parameters & Modes Digital LED Display Header (Note 4) |
L-------------------------------- | Common LED Header | |
Z-------------------------------- | Pointer Header | |
N-------------------------------- | No Header | |
Electrical Connection | 5-------------------------------- | M20x1.5 Waterproof Concentrator |
Power Supply | -A------------------------------- | 24VDC |
-B------------------------------- | 12VDC | |
Additional Type | -NF1---------------------------- | Ex-proof Certificate: Exd II CT6 |
-NS1---------------------------- | Intrinsic Safety Type: Exi II CT4 | |
-M------------------------------- | Other Requirements(Note5) | |
Remarks: | ||
e.g.:ML2088WLM6L5-A-NF1 0-1.6MPa | ||
e.g.:ML2051WLM7D5-B-NS1 0-2.5MPa | ||
Note1: Please indicate the flange size behind type if you choose this code | ||
Note2: Please indicate the thread size behind type if you choose this code | ||
Note3: Please indicate specific range behind type | ||
Note4: Only output code1 is available | ||
Note5: Please note in order | ||
*: Standard |
5. Product Photos