Vortex Flow Meter DN100 Made in China with RS485 Output
1. Introduction
LUGBML is based on vonkarman's vortex principle and uses piezoelectric crystals as the test element. It is a new type of stress detection vortex flowmeter. It has the advantages of large turndown ratio, high accuracy, small pressure loss, good medium versatility, pulse output proportional to flow rate, and convenient connection with computer. Because the sensor's detection probe and eddy current generator are installed separately, the high temperature resistant piezoelectric crystal is not The contacting instrument has simple structure, good versatility and high stability. LUGBML series vortex flowmeter sensors can be used to detect and measure the flow of various gases, liquids and steam. It can be used with our company's ML6000 series vortex flowmeter. It can also cooperate with a computer and temperature, pressure, and density sensors to form a high-precision mass flow or heat flow detection system.
2. Features
3. Specifications
1) Measuring medium: Steam,gas, liquid(Avoid of multiple- direction fluid)
2) Accuracy:Liquid:1.0% Gas:1.5%
3) Repeatability:Liquid 0.33% Gas:0.5%
4) Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s
5) Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)
6) Fluid temperature:-40℃~250℃(Common type);100℃~350℃(High-temperature type)
7) Body material:304 stainless steel(SS316 is optional)
8) Output signal:Pulse(three wires,low level≤1V;High level≧4V);4~20mA;RS485
9) Power supply:24VDC(12VDC),Lithium battery
10) Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD ); -5℃~60℃(with LCD)
11) Relative humidity:5~95%
12) Protection level:IP65
13) Electrical connection:M20*1.5
4. Dimensional Sketche
DN | A(mm) | B(mm) | C(mm) |
25 | 65 | 65 | 368 |
32 | 66 | 65 | 374 |
40 | 80 | 76 | 382 |
50 | 80 | 89 | 388 |
65 | 93 | 102 | 402 |
80 | 100 | 114 | 408 |
100 | 126 | 136 | 435 |
125 | 146 | 160 | 463 |
150 | 166 | 182 | 489 |
200 | 196 | 248 | 543 |
250 | 210 | 282 | 596 |
300 | 240 | 334 | 648 |
5. Design & Installation
The installation of the instrument is very important, if the installation is not good, it will affect the accuracy, service life and damage.
1. In order to avoid high-power, high-frequency, high-power switch groups, instrument power supplies should be avoided near these devices.
2. Avoid high temperatures and radiation sources. If installation is required, thermal insulation and ventilation measures should be taken.
3. In order to avoid high temperature and enchanted gas, ventilation measures should be taken if installation is needed.
4. The eddy current flowmeter should not be installed in the sloshing part of the pipe. If it must be installed on it, a clamping device and a vibration pad located in 2D should be added to enhance shock resistance. It is best to install the instrument indoors, pay attention to waterproof during outdoor installation, and pay special attention to the joint to make the cable wire U-shaped, so as to prevent water from entering the amplifier body, and enough space should be saved at the installation place for installation and routine maintenance.