Low Flow Divided Type Electromagnetic Flow Meter Ex-proof JIS 10K Flange
1. Introduction
MLF electromagnetic Flowmeter works according to Faraday's law of electromagnetic induction and is composed of sensors and converters. Used to measure the electrical conductivity of liquids or solids. In general, its electrical conductivity should be greater than 5 μ S / cm (the electrical conductivity of tap water and raw water is about 100 ~ 500 μS / cm), can also be used to measure various media such as acid, alkali, salt water, pulp or pulp. But these media cannot contain large amounts of magnetic materials and bubbles.
MLF electromagnetic Flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, waterworks and other industries.
2. Features
MLF electromagnetic Flowmeter is explosion-proof design.
function of low conductivity measurement.
There are 9 languages options to meet the needs of different customers.
Have self-regulation function and self-examination.
different outputs are optional: hart, RS485 Profibus ,4-20 mA, frequency, pulse.
3. Specification
MLF Type | Divided Type | Integrated Type | Explosive Proof Integrated Type | Battery Powered Type | Heat Energy Type |
Accuracy | ±0.2% or ±0.5% | ||||
Pipeline Diameter | DN10-DN2000 | DN10-DN600 | DN25-DN2000 | ||
Flange | GB, ANSI, JIS, BS, Others | ||||
Pressure | DN10-DN600 1.0 1.6 2.5 4.0MPa | ||||
DN700-DN2000 0.6 1.0 1.6MPa | |||||
Liner Material | CR, PTFE, PU, Hard Rubber, PFA, FEP(F46) | ||||
Conductivity | ≥5µs/cm(Please contact us if it is less than 5µs/cm) | ||||
Electrode | 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others | ||||
Protection Class | IP65, IP66, IP67, IP68 | ||||
Medium Temperature | -25~180℃ (Please refer to liner material) | -25~80℃(Please refer to liner material) | -25~180℃ (Please refer to liner material) | ||
Ambient Temperature for Accuracy Influence | <±0.1%/10℃ or <±0.25%/10℃ at the ambient temperature of -25~60℃ | ||||
Repetability | ≤±0.1% or ±0.25% | ||||
Analog Output Error | ≤±0.02mA | ||||
Velocity | 0.3~10m/s | ||||
Electrical connection | M20x1.5 Seal Cartridge, GB1/2, NPT1/2 | ||||
Output | 4-20mA, Pulse, RS485, Hart, Profibus |
4. Selection of Liner Material
Liner Material | Main Performance | Application |
PTFE | 1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion. 2 Low wear resistance. 3 Low negative pressure resistance. | 1. -25~140℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare medium |
CR | Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc. | 1. <80℃ 2. Be able to measure sewage and mud |
PU | 1. Very good abrasive resistance, flexibility. 2. Low acid and alkali resistance. | 1. <65℃ 2. Neutral strong abrasion resistance medium |
Hard Rubber | 1 Room temperature resistance, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide 2 Avoid strong oxidants | 1. <80℃ 2. General acid, alkali, salt solution |
PFA | 1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant. 2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 3. Injection molding for higher negative pressure | 1. 40~180℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
FEP(F46) | 1. Hydrophobicity and non-viscous 2. Corrosion resistance is inferior to PFA 3. Negative pressure | 1. 40~180℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
5. Dimensional Sketches
a. Dimension of Converter
Divided Type
Integrated Type
Battery Powered Type
b. Dimension of Sensor
Pipeline Diameter | Dimension | ||
L | W | H | |
15 | 160 | 95 | 130 |
20 | 160 | 105 | 137 |
25 | 160 | 115 | 150 |
32 | 160 | 135 | 160 |
40 | 200 | 145 | 175 |
50 | 200 | 160 | 185 |
65 | 200 | 180 | 205 |
80 | 200 | 195 | 215 |
100 | 250 | 215 | 235 |
125 | 250 | 245 | 275 |
150 | 300 | 280 | 300 |
200 | 350 | 335 | 355 |
250 | 400 | 400 | 405 |
300 | 500 | 455 | 460 |
350 | 500 | 515 | 520 |
400 | 600 | 575 | 580 |
450 | 600 | 635 | 630 |
500 | 600 | 710 | 685 |
600 | 600 | 835 | 795 |
700 | 700 | 905 | 910 |
800 | 800 | 1020 | 1030 |
900 | 900 | 1120 | 1120 |
1000 | 1000 | 1245 | 1250 |
1200 | 1200 | 1465 | 1470 |
6. Configuration
MLF Series Electromagnetic Flow Meter Configuration | |||||||||||||||||||||||
Model | MLF | ||||||||||||||||||||||
Sensor Installation | S | Flange Type Sensor | |||||||||||||||||||||
C | Insertion Type Sensor | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipeline Diameter | 10 | 10mm | |||||||||||||||||||||
15 | 15mm | ||||||||||||||||||||||
20 | 20mm | ||||||||||||||||||||||
...... | |||||||||||||||||||||||
2000 | 2000mm | ||||||||||||||||||||||
Electrode Installation | F | Standard Fixed Type | |||||||||||||||||||||
Electrode Material | A | 316L SS | |||||||||||||||||||||
B | Hb | ||||||||||||||||||||||
C | Ta | ||||||||||||||||||||||
D | Ti | ||||||||||||||||||||||
E | Hc | ||||||||||||||||||||||
F | Tungsten Carbide | ||||||||||||||||||||||
G | Others | ||||||||||||||||||||||
Liner Material | R | Rubber | |||||||||||||||||||||
P | PTFE | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipe Material | B | 304 SS (Standard) | |||||||||||||||||||||
C | 316 SS | ||||||||||||||||||||||
Flange Type | G | GB (Standard) | |||||||||||||||||||||
A | ANSI | ||||||||||||||||||||||
J | JIS | ||||||||||||||||||||||
B | BS | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Flange Material | A | 304 SS | |||||||||||||||||||||
B | 316 SS | ||||||||||||||||||||||
C | #20 Carbon Steel (Standard) | ||||||||||||||||||||||
Cover Material | D | 304 SS | |||||||||||||||||||||
E | 316 SS | ||||||||||||||||||||||
F | Carbon Steel+ Epoxy Metallic Paint (Standard) | ||||||||||||||||||||||
Matching Flange | 0 | Without Matching Flange (Standard) | |||||||||||||||||||||
1 | With Matching Flange | ||||||||||||||||||||||
Ground Ring | 0 | Without Ground Ring (Standard) | |||||||||||||||||||||
1 | With Ground Ring | ||||||||||||||||||||||
Rated Pressure | 10 | 1.0MPa | |||||||||||||||||||||
16 | 1.6MPa | ||||||||||||||||||||||
25 | 2.5MPa | ||||||||||||||||||||||
40 | 4.0MPa | ||||||||||||||||||||||
Working Temperature | E | ≤60℃ | |||||||||||||||||||||
H | ≤180℃(Divided Type) | ||||||||||||||||||||||
Type | I | Integrated Type | |||||||||||||||||||||
D | Divided Type | ||||||||||||||||||||||
Output | P | Pulse | |||||||||||||||||||||
A | 4-20mA | ||||||||||||||||||||||
G | RS485 | ||||||||||||||||||||||
H | Hart | ||||||||||||||||||||||
Q | Others | ||||||||||||||||||||||
Power Supply | 0 | 220VAC | |||||||||||||||||||||
1 | 24VDC | ||||||||||||||||||||||
2 | Battery-powered | ||||||||||||||||||||||
Protection Class | 0 | IP65 (Integrated/Divided Type) | |||||||||||||||||||||
1 | IP67 (Divided Type) | ||||||||||||||||||||||
2 | IP68 (Divided Type) | ||||||||||||||||||||||
Other Features | R | Heat Energy Function | |||||||||||||||||||||
P | With PT1000 | ||||||||||||||||||||||
B | Without PT1000 | ||||||||||||||||||||||
Explosion Proof | 0 | None | |||||||||||||||||||||
EX | Explosive Proof |
7. Instrument Testing & Maintenance
The electromagnetic Flowmeter has the function of self-diagnosis.In addition to power supply and hardware circuit failures, the system also gives an alarm to other faults in general use.These messages are prompted in the lower right corner of the screen.
1 Maintenance and repair.
A) The sensor installation site should meet the requirements of Section 4, please keep the shell clean and tidy.
B) The transmitter should be placed in a clean, ventilated and dry place.
C) It needs to be checked every two years, and for high-precision users, the instrument needs to be submitted for review.
2 Transportation and storage.
A) The equipment must be packed before transportation and handled carefully during loading and unloading.
B) The storage place must be dry and ventilated to avoid the erosion of corrosive gases and the ambient temperature should not be too low or too high.
C) The storage time should not exceed three years.
3. Out-of-the-box inspection.
A) The package cannot be opened with a heavy hammer, be careful not to damage the instrument.
B) Carefully check the contents according to the packing list.