DN40 Diameter 4-20mA Steam Vortex Flowmeter
1. Features
2. Configuration
LUGBML Series Vortex Flow Meter Configuration | |||||||||||||
Model | LUGBML | ||||||||||||
Sensor Installation | D | Clamp Type Sensor | |||||||||||
F | Flange Type Sensor | ||||||||||||
C | Insertion Type Sensor | ||||||||||||
Medium | L | Liquid | |||||||||||
G | Gas | ||||||||||||
S | Steam | ||||||||||||
Pipe Material | 25 | 25mm | |||||||||||
...... | |||||||||||||
300 | 300mm | ||||||||||||
Power Supply | A | Duplicate Supply(24VDC/12VDC+3.6V Lithium Battery) | |||||||||||
B | 3.6V Lithium Battery | ||||||||||||
C | 24VDC/12VDC | ||||||||||||
Display | D | With Digital Display | |||||||||||
P | Without Digital Display | ||||||||||||
Output | N | None | |||||||||||
P | Pulse | ||||||||||||
A | 4-20mA | ||||||||||||
R | RS485 | ||||||||||||
H | Hart | ||||||||||||
Flange Type | G | GB (Standard) | |||||||||||
A | ANSI | ||||||||||||
J | JIS | ||||||||||||
B | BS | ||||||||||||
O | Others | ||||||||||||
Sensor Material | A | 304 SS (Standard) | |||||||||||
B | 316 SS | ||||||||||||
O | Others | ||||||||||||
Medium Temperature | E | 40~250℃ | |||||||||||
H | 100~350℃ | ||||||||||||
Rated Pressure | 16 | 1.6MPa | |||||||||||
25 | 2.5MPa | ||||||||||||
40 | 4.0MPa | ||||||||||||
O | Others | ||||||||||||
Protection Class | 0 | IP65 | |||||||||||
Explosion Proof | 0 | None | |||||||||||
EX | Explosive Proof |
3. Design & Installation
The installation of the instrument is very important, if the installation is not good, it will affect the accuracy, service life and damage.
1. In order to avoid high-power, high-frequency, high-power switch groups, instrument power supplies should be avoided near these devices.
2. Avoid high temperatures and radiation sources. If installation is required, thermal insulation and ventilation measures should be taken.
3. In order to avoid high temperature and enchanted gas, ventilation measures should be taken if installation is needed.
4. The eddy current flowmeter should not be installed in the sloshing part of the pipe. If it must be installed on it, a clamping device and a vibration pad located in 2D should be added to enhance shock resistance. It is best to install the instrument indoors, pay attention to waterproof during outdoor installation, and pay special attention to the joint to make the cable wire U-shaped, so as to prevent water from entering the amplifier body, and enough space should be saved at the installation place for installation and routine maintenance.