Portable Clamp On Ultrasonic Flow Meter
I. Introduction
II. Working Principle
The external clamp type or pipe section type ultrasonic flow meter is based on the principle of "velocity difference method" to measure the liquid flow in the pipe. It adopts advanced multi pulse technology, digital signal processing technology and error correction technology, so that the flow meter can adapt to the environment of industrial field, and the measurement is more convenient, economical and accurate. The products have reached the advanced level at home and abroad, and can be widely used in the fields of petroleum, chemical industry, metallurgy, electric power, water supply and drainage, etc.
III. Specification
Performance | |
Velocity Range | ±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s) |
Accuracy | ±1% of measured value |
Repeatability | 0.2% of measured value |
Linearity | ±1% |
Pipe Size | DN25~DN1200(A pair of sensors) |
Function | |
Output | Analog output: 4~20mA, max load 750Ω. |
Pulse output: 0~10KHz | |
Communication | RS485 Modbus |
Power Supply |
Rechargeable Lithium Battery Power,3000mAh
|
Display | 240*128 back lit LCD |
Temperature | Transmitter: -14℉~140℉(-20℃~60℃) |
Transducer:-40℉~176℉(-40℃~80℃,D1) | |
Transducer:-40℉~266℉(-40℃~130℃,D1U) | |
Humidity | Up to 99% RH,non-condensing |
Physical | |
Transmitter | NEMA13, IP54 |
Transducer | Encapsulated design,IP68 |
Double-shielded transducer cable | |
Standard/maximum cable length:30ft/1000ft(9m/300m) |
IV. Configuration
Model | Transmitter |
ML-6100P | PortableType |
Velocity Range:±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s) | |
Accuracy :±1% of the measure value | |
Repeatability:0.2% of the measure value | |
Display:240*128 back lit LCD | |
Internal Lithium Power Supply: 3000mA | |
Transmitter Enclosure: IP54 | |
Output: OCT pulse output 0-10KHz, Relay output, 4-20mA for option | |
Communication: RS485 | |
Code | Type of Trnansmitter |
1 | Ultrasonic Flow Meter |
2 | Ultrasonic Energy / BTU Meter(RTD) |
Code | Transducer |
D1 | Clamp-on, IP68. Operating temperature:-40 ℉ ~ +176 ℉(-40℃ ~ +80 ℃) |
D1U | Clamp-on, IP68. Operating temperature:-40 ℉ ~ +266℉(-40℃ ~ +130 ℃) |
Code | Type of Mounting Bracket |
ST |
Single guide mounting type bracket
|
DT |
Double guide mounting type bracket
|
Code | Transducer Cable Length |
P5 | Standard length 16ft (5m) |
PXX |
XX is the length you need for cables, Maximum length is up to 30m.
|
Code | Temperature Transducer |
PT1000 | PT1000 temperature transducer+RTD module(option) |
V. Accessories