HCT380 Coating Thickness Gauge is used to measure thickness of non-magnetic coating layers covered on magnetic substrate. Such as: non-magnetic (aluminum, chrome, copper, enamel, paint) covered on magnetic substrate (steel, alloy and magnetic stainless steel), also can measure thickness of non-conductive coatings layers covered on conductive substrate. Such as: (enamel, rubber, paint, plastic) covered on conductive substrate (aluminum, brass, zinc and nonmagnetic stainless steel).
Coating layer thickness gauge tools for measuring non-magnetic coating layer.
Item | Parameter |
Measuring Range | Standard 0~1250μm (MAX 10000μm with probe F10) |
Resolution | 0.1μm/1μm |
Working Principle | Magnetic & Eddy |
Substrate | FE / NFe base, depends on probes |
Accuracy | ±2%H+1μm Note: H is thickness reading |
Display | 128x64 LCD with backlight |
Memory | 5 files x 99 values |
Unit Switch | Metric (μm) Imperial (mil) |
Working Temperature | Operation Temp. :-10°C~50°C Storage Temp. :-30°C-70°C |
Power | AA battery 2pcs (Non-aviation transport) |
Size | 125x67x31mm |
Weight | 340g |
![]() | F1 probe - Fe base Measuring range: 0~1250μm F1 probe measure the thickness of non-magnetic coating layers covered on magnetic substrate. Such as: non-magnetic (aluminum, chrome, copper, enamel, rubber, paint) covered on magnetic substrate (steel, alloy and magnetic stainless steel) |
![]() | N1 probe - Al base Measuring range: 0~1250μm N1 probe can measure the thickness of non-conductive coatings layers covered on conductive substrate. Such as: (enamel, rubber, paint, vanish, plastic anodic-oxide layer) covered on conductive substrate (aluminum, brass, zinc and nonmagnetic stainless steel). |
![]() | F1/90°probe - Fe base Measuring range: 0~1250μm F1/90°use to measuring surface that can’t be touch by ordinary probe, it can measure the thickness of non-magnetic coating layers covered on magnetic substrate. Such as: non-magnetic (aluminum, chrome, copper, enamel, rubber, paint) covered on magnetic substrate (steel, alloy and magnetic stainless steel) |
![]() | F10 probe - Fe base (Large range) Measuring range: 0~10000μm F1 probe measure the thickness of non-magnetic coating layers covered on magnetic substrate. Such as: non-magnetic (aluminum, chrome, copper, enamel, rubber, paint) covered on magnetic substrate (steel, alloy and magnetic stainless steel) |
![]() | Standard coating thickness calibration pieces Standard thickness value between 0~1250μm 5pcs/set, include Fe or Al base |
Standard coating thickness calibration pieces (Large range) Standard thickness value between 0~10000μm 5pcs/set, include Fe or Al base |