Factory Price XLPE Insulated PVC Sheath 15 kV Cable 1x240 mm2 Power Cable
![]() | Example Specification | 3*70 mm2 |
Conductor Material | Copper | |
Constitude Structure | 19/2.18 | |
Conductor Diameter | 10.0mm | |
Insulation Material | XLPE | |
Insulation Mean Thicness | 10.5mm | |
Conductor Tape | 60*0.20 | |
Jacket Material | PVC |
onstruction characteristics | |
Conductor shape | Circular stranded (RM) |
Lead free | Yes |
Insulation | XLPE |
Screen | copper tape |
Material of bedding | Separation tape |
Outer sheath | PVC |
Usage characteristics | |
Packaging | Steel Wooden Drum |
Minimum installation temperature | -20 °C |
Max. conductor temperature in service | 90 °C |
Short-circuit max. conductor temperature | 250 °C |
Bending factor when laying | 20 (xD) |
ross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
3×35 | 7 | 4.5 | 2.6 | 51.3 | 0.524 |
3×50 | 10 | 4.5 | 2.7 | 53.8 | 0.387 |
3×70 | 14 | 4.5 | 2.8 | 57.5 | 0.268 |
3×95 | 19 | 4.5 | 3.0 | 62.0 | 0.193 |
3×120 | 24 | 4.5 | 3.1 | 65.2 | 0.153 |
3×150 | 30 | 4.5 | 3.2 | 68.3 | 0.124 |
3×185 | 37 | 4.5 | 3.3 | 72.3 | 0.0991 |
3×240 | 48 | 4.5 | 3.5 | 77.9 | 0.0754 |
3×300 | 61 | 4.5 | 3.7 | 84.3 | 0.0601 |
3×400 | 61 | 4.5 | 3.9 | 91.9 | 0.0470 |
3×500 | 61 | 4.5 | 4.1 | 100.7 | 0.0366 |
3×630 | 61 | 4.5 | 4.4 | 109.7 | 0.0283 |
MEDIUM VOLTAGE CABLE TESTING
Routine tests: | Sample tests: | Type tests: |
These non-destructive tests are normally carried out on all lengths manufactured. - Conductor resistivity - Spark test on oversheath - Voltage tests on sheath - D.C. voltage test on oversheath | These potentially destructive tests are normally carried out on every production run. - Examination of conductor and dimensions - Hot set test for XLPE insulation - Insulation and oversheath thickness - Four hour voltage test | These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design. - Electrical type tests including bending and heat cycle - Non-electrical type tests including mechanical properties after ageing and tests under fire conditions. |
▼ Cable Drum Data:
CABLE DRUMS | D1=Flange Diameter(mm) | W=Useful Width (mm) | D2=Barrel Diameter(mm) |
![]() | 1000 | 700 | 500 |
1100 | 700 | 550 | |
1200 | 700 | 600 | |
1400 | 750 | 710 | |
1600 | 900 | 900 | |
1800 | 1120 | 1000 | |
2400 | 1150 | 1300 |
▼ Payment:
We usually use T/T
T/T deposit before production and balance when shipment.
Payment terms: Western Union, Escrow, Paypal, T/T, L/C
▼ Shipping:
For big orders, we will ship the goods by air or by sea.