Product Introduction:
Hydrocarbon gas is second only to a fixed by wall-mounted installation, pipeline installation and circulation type (stack) are widely used in: petrochemical, industrial production, smelting, forging, electric power, coal mine, tunnel engineering, environmental monitoring, wastewater treatment, biological, pharmaceutical, household environmental protection, animal husbandry and aquaculture, greenhouse cultivation, warehousing logistics, brewing fermentation, agricultural production, fire, gas, building construction, municipal enterprises, school laboratory, research center and other industries.
Product features:
Technical parameters:
Detection principle: PID photoionization
Installation: fixed, wall - mounted, pipe - type
Measurement range: 0-1000ppm, 0-2000ppm, 0-3000ppm, 0-6000ppm (optional)
Resolution: 0.01 POPM, 0.1 PPM
Pure c: plus or minus 2% FS
Zero drift: ≤±1% (FS/ year)
Repeatability: ≤±1%
Signal output: 4-20MA, RS485(optional), relay output (optional)
Response time: ≤10S
Reply time: ≤10S
Screen display: digital tube
Connection thread: G1/2
Explosion-proof grade: Ex d Ⅱ CT6
Protection level: IP65
Operating temperature: -20℃ -- 50℃