Specification of the 20kVA Diesel Generator:
Model | A-P22 | |
Max. Power | kVA | 22 |
kW | 17.6 | |
Rate Power | kVA | 20 |
kW | 16 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 28.9 |
Fuel Tank Capacity | L | 50 |
Dimension For Open-type Genset | mm | 1390 X 550 X 1200 |
Weight For Open-type Genset | kg | 493 |
Dimension For Soundproof Genset | mm | 1950 X 800 X 1250 |
Weight For Soundproof Generator | kg | 673 |
Noise Level for Soundproof Generator at 7M | dBA | 72 |
Battery for Starting | One of 60A Free Maintenance Battery |
Specification of Perkins Diesel Engine:
Engine Manufacturer | Perkins | |
Engine Brand | Perkins | |
Engine Model | 404D-22G | |
No. of Cylinder | 4 Cylinder in line | |
Aspiration | Naturally Aspirated | |
Governor | Mechanical | |
Engine Max. Output Power | kW | 20.6 |
Displacement | L | 2.216 |
Compression Ratio | 23.3 : 1 | |
Starting Voltage | V | 12 |
Bore | mm | 84 |
Stroke | mm | 100 |
Lubrication Oil Capacity | L | 10.6 |
Intake Air Flow | M3/Min | 1.45 |
Fuel Consumption at 100% Load | L/H | 5.3 |
Specification of Stamford Alternator PI 144 D:
Alternator Manufacturer | Cummins Generator Technologies | |
Alternator Model | PI 144D | |
Alternator Brand | Stamford | |
Rate Output | kVA | 20 |
Frequency | Hz | 50Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Phase | 3 Phase | |
Working Temperature without power decrease | ≤40℃ | |
Working Altitude without power decrease | ≤1000m | |
Automatic Voltage Regulation | SX480 | |
Protection Grade | IP23 | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Specification of Control Panel:
Controller Brand | Deepsea | |
Controller Model | DSE7320 | |
Breaker Brand | Delixi | |
Breaker Capacity (A) | 32 | |
Battery Charger | Smartgen Model BAC06A | |
Emergency Stop Button | Supply | |
Automatic Mains Fail (AMF) | Supply | |
Fuel Level | Supply | |
Automatic Transfer Switch | ATS as optional part | |
The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm). | ||
Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. |
Rated output: There is no time limit in the case of variable load operation. In any 250hours of continuous operation period, the variable load of average working load less than 70%of the prime power. The operation time in the situation of 100% prime power no more than 500 hours. Permit 10%overload running1hours in any 12 hours of continuous operation period. The overload 10% power running time of every year no more than 25 hours.
Max. Power: The annual total standby power load should be less than 80% and the average running time shall be less than 200 hours. Among them, the standby power point should be no more than 25 hours a year.