NOTE: It is beyond the scope of this document to program the V1000 drive for network communication control. Please refer to the programming manual for this selection.
• Compact and programmable
• EMC tested. CE-marked
• Built-in RS232/RS485 Interface
• Models with sequential program execution
• Simple programming using MotoWare
• Facilities for graphic monitoring
• Electronic gearing with high resolution
• Use FLASH-PROM, can be re-programmed
• Absolute or relative positioning • Programmable velocity profiles
• Driver stages of 6 and 12A • Digital control loop
• Automatic zero-point seek
• 11 inputs, 8 outputs
• Current and voltage overload protection
• Short-circuit and thermal overload protection
• End-of-travel limit inputs
Parameter Default Value Description Comments b1-01 1 Reference Source Speed Control Method 0 = Digital Operator (Adjust Motor Speed from keypad) 1
= Terminals (Speed Pot. / 0 – 10V / 4—20mA) b1-02 1 Run Source / Start/Stop Control Method 0 = Digital Operator (Start/Stop motor from keypad) 1
= Terminals (Start/Stop using external contact / switch) b1-03 1 Stop Method Selection 0 = Ramp to stop (Motor ramps down at stop command) 1
= Coast to stop (Motor freewheels at stop command) b1-04 0 Reverse Operation 0 = Allow motor to run in reverse direction 1
= Reverse direction prohibited C1-01 10.0 sec. Acceleration Time The time it takes to ramp up from 0 to maximum motor speed. C1-02 10.0 sec. Deceleration Time The time it takes to ramp down from maximum motor speed to 0. C6-01 1 Normal / Heavy Duty 0
=Normal Duty (Use for fan and pump applications) 1
= Heavy Duty (Use for conveyor, mixer, applications) d1-01 0.00 Hz Frequency Reference Frequency setting when speed is set from the keypad. d2-01 100.0 % Frequency Upper Limit Maximum motor speed allowed (e.g. 100 % = Max rpm) d2-02 0.0 % Frequency Lower Limit Minimum motor speed allowed (e.g. 100 % = Max rpm) E2-01 * Motor Rated Current Motor nameplate current L1-01 1 Motor Overload Selection 0 = Disabled 1
= Standard Fan Cooled Motor 2 = Standard Blower Cooled Motor 3
= Vector Duty Motor L1-02 1.0 min Motor Overload Time Sets the motor thermal overload protection time.