Specifications
Brand Name :
Honeywell
Model Number :
STT700
Place of Origin :
America
MOQ :
1
Price :
negotiable
Payment Terms :
T/T
Supply Ability :
100
Delivery Time :
5-8 work days
Packaging Details :
New in original box
Certification :
CE
brand :
Honeywell
model :
STT700
origin :
America
Output :
4-20 mA DC
Version :
HART ® (version 7.0)
Digital accuracy :
up to 0.15 Deg C for Pt100
Description

Pressure Temperature Transmitter STT700 SmartLine Digital accuracy up to 0.15 Deg C for Pt100 4-20 mA DC

Introduction

Part of the SmartLine® family of products, the SmartLine STT700 is a high performance temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures. SmartLine easily meets the most demanding needs for temperature measurement applications.

Best in Class Features:

The STT700 is single or a dual input temperature transmitter that supports millivolt, thermocouple and RTD sensors. It is available with either HART or DE protocol output.

High performance

o Digital accuracy up to 0.15 Deg C for Pt100

o Stability up to ±0.05% of URL per year for ten years

o 500 mSec update time (single input)

o 1 Sec update time (dual input)

Reliable measurement

o Built in galvanic isolation

o Sensor break detection

o Comprehensive on-board diagnostic capabilities

o Full compliance to SIL 2/3 requirements.

o Available with 4 year warranty o Supports Namur 89 Wire break

o Direct entry of Callendar-van Dusen coefficients R0, α, δ and β for calibrated RTD sensors.

Lower Cost of Ownership

o Universal input

o Dual sensor option

o External zero, span, & configuration capability

o Polarity insensitive loop wiring

Communications/Output Options:

o 4-20 mA DC

o HART ® (version 7.0)

o Honeywell Digitally Enhanced (DE)

All transmitters are available with the above listed output and communications protocol option.

Mounting Options:

o Direct sensor head mounting in DIN Form A aluminum housing.

o Other mounting options available include wall, pipe, DIN Rail or single compartment field housing.

Instructions:

Make selections from all Tables Key through XIII using column below the proper arrow. Asterisk indicates availability. Letter (a) refer to restrictions highlighted in the restrictions table. Tables delimited w ith dashes.

HART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DCHART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DCHART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DCHART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DCHART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DCHART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DC

Differential Temperature Measurement

SmartLine STT700 Temperature supports differential temperature measurements for dual input transmitters. When the loop current mode is set to "Differential" then the input range is from A to B for sensor 1 & 2 where

A = Sensor 1 Minimum - Sensor 2 Maximum

B = Sensor 1 Maximum - Sensor 2 Minimum

Digital Accuracy for differential temperature measurement

 If both input types are the same, then the digital accuracy equals 1.5 times the worst case accuracy for that input type.

 If the input types are different, then the digital accuracy equals the sum of the worst case sensor 1 and sensor 2 accuracies. For example, assume that input 1 is a J T/C and input 2 is an R T/C. Assume that the desired operating range is between 0 and +400 °C. The digital accuracy for a J T/C in this range is 0.30 °C and the digital accuracy for an R T/C in this range is 1.00 °C. Therefore, the worst case digital accuracy would be 1.30 °C.

Performance under Rated Conditions – All models

Stray Rejection

Common Mode

AC (50 or 60 Hz): 120 dB (with maximum source impedance of 100 ohms) or ± 1 LSB (least significant bit) whichever is greater with line voltage applied.

DC: 120 dB (with maximum source impedance of 50 ohms) or a ±1 LSB whichever is greater with 120 VDC applied.

DC (to 1 KHz): 50 dB (with maximum source of impedance of 50 ohms) or ±1 LSB whichever is greater with 50 VAC applied. Normal Mode

AC (50 or 60 Hz): 60 dB (with 100% span peak-to-peak maximum)

EMC Compliance EN 61326-1 and EN 61326-3-1 (SIL)
Lightning Protection Option

Leakage Current: 10 uA max @ 42.4 VDC 85 °C

Impulse rating: 8/20 uS 5000 A (>10 strikes) 10000 A (1 strike min.)

10/1000 uS 200 A (> 300 strikes)

Materials Specifications - All models

Parameter Description
Terminal Block and Module Housing Lexan 500R (Polycarbonate, Glass Fiber Reinforced 10%)
Connection Screws M3 Nickel Plated Brass
Weight 0.075 kg (0.2 lbs)

HART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DC

HART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DC

Send your message to this supplier
Send Now

HART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DC

Ask Latest Price
Brand Name :
Honeywell
Model Number :
STT700
Place of Origin :
America
MOQ :
1
Price :
negotiable
Payment Terms :
T/T
Contact Supplier
HART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DC
HART 7.0 Version Pressure Sensor Transmitter Up To 0.15 Deg C For Pt100 4-20 MA DC

Shenzhen Wisdomlong Technology CO.,LTD

Verified Supplier
8 Years
guangdong, shenzhen
Since 2010
Business Type :
Importer, Exporter, Trading Company, Seller
Total Annual :
1000000-5000000
Employee Number :
100~120
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement