Industrial Motor Yaskawa 50W 200V Servo Motor SGMAS-A5A2A2C new in box
QUICK DETAILS
Model Number:SGMAS-A5A2A2C
Type: Servo Motor
Frequency: 50/60Hz
Output Power: 50W
Protect Feature:Totally Enclosed
Phase:Three-phase
Certification:CCC, CE, ROHS, UL, VDE, Other
AC Voltage:208-230 / 240 V
Place of Origin:Japan
Efficiency:IE 1
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
SIMILAR PRODUCTS
SGMAS-01ACAB1 | SGMAS-01ACA61-Y2 |
SGMAS-01ACA2C | SGMAS-01ACA61 |
SGMAS-01A2A-YR11 | SGMAS-01ACA21 |
SGMAS-01A2A-FJ12 | SGMAS-01A2A-FJ13 |
SGMAS-01A2AA1-E | SGMAS-01A2A4C |
SGMAS-01ACA2C | SGMAS-01ACA21 |
SGMAS-01A2A-YR11 | SGMAS-01A2A-FJ13 |
SGMAS-01A2A-FJ12 | SGMAS-01A2AA1-E |
SGMAS-01A2A4C | SGMAS-01A2A2C |
SGMAS-01A2A21/C | SGMAS-01A2A21 |
Power supply
(a) Operate the servo amplifier to meet the requirements of the overvoltage category II set forth in IEC60664-1. For this purpose, a reinforced insulating transformer conforming to the IEC or EN Standard should be used in the power input section.
(b) When supplying interface power from external, use a 24VDC power supply which has been insulation-reinforced in I/O.
Grounding
(a) To prevent an electric shock, always connect the protective earth (PE) terminals (marked ) of the servo amplifier to the protective earth (PE) of the control box.
(b) Do not connect two ground cables to the same protective earth (PE) terminal as shown at right below. Always connect the cables to the terminals one-to-one.
(a) Motor Frame
Always connect servomotor frame terminal FG to the SERVOPACK ground terminal . Also be sure to ground the ground terminal .
If the servomotor is grounded via the machine, a switching noise current will flow from the SERVOPACK power unit through motor stray capacitance. The above grounding is required to prevent the adverse effects of switching noise.
(b) SynqNet Communication Cable
Make sure to keep the box or power line separate from the SynqNet communication cable because the cable is easily influenced by noise.
If noise is a problem, coil the communication cable two turns around the ferrite cores on the SERVOPACK end and the controller end. Refer to the following diagram.
(c) Noise on the Reference Input Line
If the reference input line receives noise, ground the 0 V line (SG) of the reference input line. If the main circuit wiring for the motor is accommodated in a metal conduit, ground the conduit and its junction box. For all grounding, ground at one point only.
All grounds must be made to only one point in the system.
Using Noise Filters
Use an inhibit type noise filter to prevent noise from the power supply line. The following table lists recommended noise filters for each SERVOPACK model.
Install a noise filter on the power supply line for peripheral equipment as necessary.