per point Isolated Form A, 8 points IC200MDL930 GE VersaMax Discrete Output Module, Relay 2 .0 A
IC200MDL750 | IC200MDL930 | IC200MDL940 | |
Product Name | VersaMax Discrete Output Module, 24 VDC Positive Logic, 0 .5A per point, 32 points | VersaMax Discrete Output Module, Relay 2 .0 A per point Isolated Form A, 8 points | VersaMax Discrete Output Module, Relay 2 .0 A per point Isolated Form A, 16 points |
Lifecycle Status | Active | Active | Active |
Output Voltage | 10 .2-30 VDC, 12/24 VDC nominal | 0-125 VDC, 5/24/125 VDC nominal; 0-265 VAC (47-63 Hz), 120/240 VAC nominal | 0-125 VDC, 5/24/125 VDC nominal; 0-265 VAC (47-63 Hz), 120/240 VAC nominal |
Number of Points | 32 | 8 | 16 |
Channel to Channel Isolation | No | Yes | Yes |
Load Current per Point | 0 .5 A per point | 2 .0 A for 5-265 VAC, 2 .0 A for 5-30 VDC, 0 .2 A for 31-125 VDC | 2 .0 A for 5-265 VAC, 2 .0 A for 5-30 VDC, 0 .2 A for 31-125 VDC |
Input and Output Response Time- On/Off (ms) | 0 .2/1 .0 | 10 .0/10 .0 | 10 .0/10 .0 |
Protection | No internal fuses | No internal fuses or snubbers | No internal fuses or snubbers |
Points per Common | 2 groups of 16 | Isolated points | Isolated points |
External Power Supply | 10 .2-30 VDC, 12/24 VDC nominal | 0-125 VDC, 5/24/125 VDC nominal; 0-265 VAC (47-63 Hz), 120/240 VAC nominal | 0-125 VDC, 5/24/125 VDC nominal; 0-265 VAC (47-63 Hz), 120/240 VAC nominal |
Load Current | 0 .5 A at 30 VDC maximum (resistive); 2 .0 A inrush maximum for 100 ms | 10 mA per point minimum; 2 .0 A for 5-265 VAC maximum (resistive); 2 .0 A for 5-30 VDC maximum (resistive); 0 .2 A for 31-125 VDC maximum (resistive) | 10 mA per point minimum; 2 .0 A for 5-265 VAC maximum (resistive); 2 .0 A for 5-30 VDC maximum (resistive); 0 .2 A for 31-125 VDC maximum (resistive) |
5V Backplane Current Consumption (mA) | 90 maximum | 245 maximum | 490 maximum |
LED Indicators | One LED per point shows individual point ON/OFF state (logic side) . FLD PWR LED indicates field power is present . OK LED indicates backplane power is present . | One LED per point shows individual point ON/OFF state (logic side) . FLD PWR LED indicates field power is present . OK LED indicates backplane power is present . | One LED per point shows individual point ON/OFF state (logic side) . FLD PWR LED indicates field power is present . OK LED indicates backplane power is present . |
Dimensions (W x H x D) | 110 mm (4 .3 in) x 66 .8 mm (2 .63 in) x 50 mm (1 .956 in), not including the height of the carrier or the mating connectors | 110 mm (4 .3 in) x 66 .8 mm (2 .63 in) x 50 mm (1 .956 in), not including the height of the carrier or the mating connectors | 110 mm (4 .3 in) x 66 .8 mm (2 .63 in) x 50 mm (1 .956 in), not including the height of the carrier or the mating connectors |
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states . Modules require a carrier base (IC200CHSxxx) .